Diagnostics
b. Enable the capture filter schedule.
c. For Duration, type the amount of time that the scheduled analyzer session will run.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Duration to ten minutes, enter 10m or 600s.
d. For Save interval, type the frequency with which captured events will be saved.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and take the
format number{w|d|h|m|s}.
For example, to set Save interval to ten minutes, enter 10m or 600s.
9. Click Apply to save the configuration and apply the change.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Add a new capture filter:
(config)> add network analyzer name
(config network analyzer name)>
4. Add an interface to the capture filter:
(config network analyzer name)> add device end device
(config network analyzer name)>
Determine available devices and the proper syntax.
To determine available devices and proper syntax, use the space bar autocomplete feature:
(config network analyzer name)> add device end <space>
(config network analyzer name)> add interface end /network/
Repeat to add additional interfaces.
5. (Optional) Set a filter for the capture filter:
a. To create a filter that either captures or ignores packets from a particular IP address or
network:
i. Add a new IP address/network filter:
(config network analyzer name)> add filter address end
(config network analyzer name filter address 0)>