Digital Input/Output and Analog Input
Analog input, 4-20mA input mode
Analog input, 0-10V input mode
Digital and analog I/O specifications
Digital I/O specifications
Specification
Rated Input Voltage
Rated Input Current
Pull-Up Resistance
1
The current limiter is limiting over 30mA.
Digital input specifications
This input is a non-inverting Schmitt-trigger input.
n
The default state at power-up with no voltage applied is LOW.
n
Specification
+ Threshold
- Threshold
Input impedance
IX30 User Guide
Digital and analog I/O specifications
Min
Nom
Max
-1.5
18.5
-1.0
100
10 k
Min
Nom
Max
..
2
..
..
1.1
..
..
4.7M
..
Units
V
1
mA
Ohms
Units
V
V
Ohms
826