Digi IX30 User Manual page 211

Table of Contents

Advertisement

Serial port
RS-485
n
l
The default is RS-232.
7. Expand Serial Settings.
The entries in the following fields must match the information for the power controller. Refer
to your power controller manual for the correct entries.
a. Baud rate: For Baud rate, select the baud rate used by the device to which you want to
connect. The default is 9600.
b. Data bits: For Data bits, select the number of data bits used by the device to which you
want to connect. The default is 8.
c. Parity: For Parity, select the type of parity used by the device to which you want to
connect. The default is None.
d. Stop bits: For Stop bits, select the number of stop bits used by the device to which you
want to connect. The default is 1.
e. Flow control: For Flow control, select the type of flow control used by the device to
which you want to connect. The default is None.
8. Expand Logging Settings to configure logging for this serial port.
a. To enable logging, click to toggle on Enable.
b. For Log File Size, type the size of the log file. When the log file reaches the size limit, the
current file is saved and a new file is created.
The log file is saved to the /opt/serial directory. Because this is being save to the device's
memory, you should use serial logging for diagnostic purposes, rather than having it
permanently enabled.
9. Click Apply to save the configuration and apply the change.
  Command line
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX30
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. The serial port is enabled by default. To disable:
(config)> serial port1 enable false
(config)>
4. Set the mode:
(config)> serial port1 mode login
(config)>
5. Set the signaling interface type used on this serial port:
IX30 User Guide
Enable Termination if you want to enable electrical termination on this serial port.
Configure Login mode
211

Advertisement

Table of Contents