Figure 16-13 shows an example of SCI operation for multiprocessor format reception.
Start
bit
1
0
D0
MPIE
RDRF
RDR
value
MPIE = 0
Start
bit
1
0
D0
MPIE
RDRF
RDR
ID1
value
MPIE = 0
Figure 16-13 Example of SCI Operation in Reception
(Example with 8-Bit Data, Multiprocessor Bit, One Stop Bit)
744
Data (ID1)
Stop
MPB
bit
D1
D7
1
RXI interrupt
RDR data read
request
and RDRF flag
(multiprocessor
cleared to 0 in
RXI interrupt
interrupt)
service routine
generated
(a) Data does not match station's ID
Data (ID2)
Stop
MPB
bit
D1
D7
1
RXI interrupt
RDR data read and
request
RDRF flag cleared
to 0 in RXI interrupt
(multiprocessor
service routine
interrupt)
generated
(b) Data matches station's ID
Start
Data (Data1)
bit
1
0
D0
D1
If not this station's ID,
MPIE bit is set to 1
again
Start
Data (Data2)
bit
1
0
D0
D1
Matches this station's ID,
so reception continues, and
data is received in RXI
interrupt service routine
Stop
MPB
bit
1
D7
0
1
Idle state
(mark state)
ID1
RXI interrupt request is
not generated, and RDR
retains its state
Stop
MPB
bit
1
D7
0
1
Idle state
(mark state)
ID2
Data2
MPIE bit set to 1
again