Register Descriptions; Standby Control Register (Sbycr) - Renesas H8S/2633 Series Hardware Manual

Hide thumbs Also See for H8S/2633 Series:
Table of Contents

Advertisement

24.2

Register Descriptions

24.2.1

Standby Control Register (SBYCR)

Bit
:
SSBY
Initial value
:
R/W
:
R/W
SBYCR is an 8-bit readable/writable register that performs power-down mode control.
SBYCR is initialized to H'08 by a reset and in hardware standby mode. It is not initialized in
software standby mode.
Bit 7—Software Standby (SSBY): When making a low power dissipation mode transition by
executing the SLEEP instruction, the operating mode is determined in combination with other
control bits.
Note that the value of the SSBY bit does not change even when shifting between modes using
interrupts.
Bit 7
SSBY
Description
0
Shifts to sleep mode when the SLEEP instruction is executed in high-speed
mode or medium-speed mode.
Shifts to sub-sleep mode * when the SLEEP instruction is executed in
sub-active mode * .
Shifts to software standby mode, sub-active mode * , and watch mode * when the
1
SLEEP instruction is executed in high-speed mode or medium-speed mode.
Shifts to watch mode * or high-speed mode when the SLEEP instruction is executed in
sub-active mode * .
Note: * This function is not available in the H8S/2695.
7
6
5
STS2
STS1
0
0
0
R/W
R/W
4
3
STS0
OPE
0
1
R/W
R/W
2
1
0
0
0
0
(Initial value)