Preparation for Use – Setting Up
4
Press the 'Full (mV)' display touch button to enter the value, OR
press 'Set' when the rinse tank is full.
Press the 'Set' touch button when the product tank is
empty to set the value.
ii) Rinse Tank Calibration
The Rinse Tank Calibration settings comprise:
'Rinse tank sensor reading (mA)' - is the current value of
the rinse tank pressure transducer sensor. This will vary
depending on volume between 1000 & 5000.
'Full (mV)' - is the value of the rinse tank pressure
transducer sensor when the rinse tank is full.
'Empty (mV)' - is the value of the rinse tank pressure
transducer sensor when the rinse tank is empty.
To Set the 'Full (mV) Set Point:
1 Press the 'Full (mV)' display touch button and a
numerical keypad appears.
2 Press the numbers to set the value between 1000 &
5000, then press Enter. The screen returns to the Tank
Calibration tab screen with eg, 2000 displayed in the
'Full (mV)' display.
OR
80
Press the 'Empty (mV)' display touch button to enter the value, OR
press 'Set' when the rinse tank is empty.
Press the 'Set' touch button when the product tank is
empty to set the value.
To Set the 'Empty (mV)' Set Point:
1 Press the 'Empty (mV)' display touch button and a
numerical keypad appears.
2 Press the numbers to set the value between 1000 &
5000, then press Enter. The screen returns to the Tank
Calibration tab screen with eg, 1400 displayed in the
'Full (mV)' display.
OR
Press the 'Set' touch button when the product tank is
empty to set the value.
The 'SAVE' touch button will appear on the left hand side of the screen if a new
value is entered or a change made in the G-Hub system.
If the 'SAVE' touch button is not pressed, then any current changes or entered
value or values will be lost and previous settings will remain.
The 'SAVE' touch button can be pressed at any stage or screen change to
ensure new settings are saved and not accidentally lost.
The screen will return to the G-Hub home screen after the 'SAVE' touch button
is pressed.
Press the Hydraulics Tab touch button to display touch button the Hydraulics tab
screen.

4 Hydraulics

Press the Hydraulics Tab touch button to open the Hydraulics
settings screen and the Hydraulics settings screen opens
displaying:
A. Spray Pump
B. Engine Fan
C. Alarms
D. Goldacres Headland Assist
E. Steering.
The Hydraulics screen is locked for protection from uninformed
or accidental alteration.
The screen must be unlocked before any setting or alterations
can be made. Refer to previous pages for details to unlock the
screen.
A. Spray Pump
Spray Pump settings comprise:
i)
Ramp Up (sec)
ii) Ramp Down (sec)
iii) Spool Valve Cal (%)
iv) High Speed Alarm (rpm)
v) Low Speed Alarm (rpm)
GA8701177 REV 2 APRIL 2022