LED KEY
LED COLOUR
Red
SYS0
Green (Flashing)
Off
SYS1
Green
ETH0
Off
ETH1
Off
Off
APP0
Blue
Red
APP1
Green
Blue
APP2
Green
Red
Green
Red
APP3
Blue
Yellow
Magenta
GA8701177 REV 2 APRIL 2022
Trouble Shooting – Fast Tracking Problems
LED lights & keys on the ISOBus Module
DESCRIPTION
PLC Error, PLC not running
PLC OK, running
No PLC power
Not used (second PLC)
No Ethernet connection
No Ethernet connection
Error
G-Hub online
No HMI settings transfer
HMI Settings transferred ok
No HMI settings changed
HMI Settings changed ok
HMI Settings changed failed
CAN OK, online
CAN RAW fault
CAN open fault
CAN ISOBUS fault
CAN J1939 fault
When nothing appears on the G-Hub screen, first, check the lights of the PCL
Controller (located in the filling station storage box) for more information.
Check the LED colours and if problem is showing according to the LED lights
Description, contact you local Dealer for service.