Hydraulic & Pneumatic
PROBLEM
COMMON CAUSES
Low hydraulic oil level
No hydraulic
pressure
Fill pump is engaged
Low system pressure
The air bags are
not inflating
Compressor not working
properly
Vehicle sits
Incorrectly adjusted ride
unevenly
height valves.
Condenser blocked
Compressor belt loose
Air conditioning
not cooling
effectively
A/C system needs re-
gassing
Evaporator blocked
GA8701177 REV 2 APRIL 2022
COMMON SOLUTION
Check the oil level in the hydraulic reservoir
and top up if necessary
Switch the hydraulic fill pump off
The bags will not inflate until the pressure in
the system is above 75 PSI, check system
pressure.
Check that the compressor is working
correctly
Adjust the ride height valves as per
the instructions in the Lubrication and
Maintenance chapter.
Check the condenser for a build up of dirt
and plant matter, clean if required
Inspect the belt to see if it is tensioned
correctly. If belt is showing signs of wear,
replace
If this is the case, only allow a qualified
air conditioning technician to work on the
system. R134a refrigerant must not be
allowed to escape to the atmosphere
Build up of dirt and plant matter, clean if
required. Be careful not to damage any of
the components