Ready to Spray – Operation
6
Density Factor
Product Tank
To be set in the cabin
Volume in litres
G-Hub Controller
Fill
4000
Product Tank Vol
Density Factor
1.0
Desired Tank Vol
5000
FILL PRESSURE
PUMP RPM
PUMP PRESSURE
40
543
125
Fill Pump
Spray
Spray
Pressure
Pump
Pump
(kPa)
RPM
Pressure
(kPa)
Desired Tank Volume
in litres
The 'Fill Screen' layout, functions & control touch buttons.

External G-Hub Controller

The External G-Hub Controller is used to control the spray pump, fill pump, agitator, rinse
nozzles and induction hopper functions independently of the cabin mounted G-Hub Controller.
The External G-Hub Controller features a 5" full colour screen and push button panel.
The Controller Screen & Push Button Panel are mounted on an adjustable RAM bracket which
allows personalised positioning for the operator.
124
RPM Raise
Increases Engine RPM for
Screen Selector
optimum oil flow
Clean
Clean
page
RPM
Raise On
Rinse Tank
400
Tank
increase
Tank
ENGINE RPM
decrease
1025
Engine
Tank Increase
Tank Decrease
RPM
Vol x 100L
Rinse Tank
Volume in litres
Fill & Clean
Spray Pump Product
Suction from Product tank
Fill Product Tank:
• Single Press -
Fill to desired tank volume
• Hold for 2 seconds -
Slow fill main tank
• Aux Functions -
(light starts flashing)
Auto RPM Raise
(Induction to Product Tank)
The 'Push Button Panel' layout with push buttons which illuminate Green (Dirty Water) or Blue (Clean Water) when engaged.
Vol x 100L
The push button switches of the Push button Panel (shown above) are organised to illuminate green or blue when engaged.
Blue light indicates Clean water engagement (clean fill, pump, rinse tank, rinsing circuits & fresh water tank) while Green indicates
Dirty water (product tank, pump, agitation, dirty fill, chemical mixing/uploading & spraying circuits .
The Controller screen displays either the:
Fill Screen - for all filling functions (shown above left) or the
Clean Screen - for all cleaning functions (shown next page)
The Push Button Panel (shown above) is positioned at the right of the Controller screen and is
used to switch liquid flows On & Off for all filling and cleaning functions.
The G-Hub External Controller allows the operator to simply enter the desired tank volume,
connect the Fill hose and the G-Hub integrated controller system automatically shuts Off when fill
volume is met.
The functional procedures for operating the Quick Filling Station & External G-Hub Controller are
provided on the pages that follow.
Dirty Water
Clean Water
Functions
Functions
Pump
Pump
Product
Rinse
On/Off
Fill
Fill
Product
Rinse
Agitator
Fill
Agitator
Pump
On/Off
Hopper
Rinse
Hopper
Nozzle
On/Off
Spray Pump Rinse
On/Off
Suction from Rinse tank
Fill Rinse Tank:
• Single press - Fills the Rinse
Tank until full (Auto Shut-Off)
If activated at the same time as
Fill Product Tank, Fill Rinse Tank
will pause (light flashing) until
Product Tank reaches 500L
Fill Pump
On/Off
Auto RPM raise
Rinse Nozzle
• On/Off - from Rinse Tank
• Hold for 2 secs - Light
flashes & flow comes from
Spray Pump
GA8701177 REV 2 APRIL 2022