Goldacres G6 Crop Cruiser 2 Series Operator's Manual page 79

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

Press the Rinse Tank display touch button settings to preset the rinse tank
functions.
The touch button displays Green when selected & Grey
when deselected.
ii) Rinse Tank
The Rinse Tank settings comprise:
'Low Tank Alarm Volume (L)' - sets the volume in litres
for the low level alarm in the rinse tank.
'Low Tank Alarm' - selects or deselects the low level
alarm of the rinse tank. To Set the Low Tank Alarm Vol
(L):
To Set the Low Tank Alarm Vol (L):
1 Press the 'Low Tank Volume (L)' display touch button
and a numerical keypad appears.
2 Press the numbers to set the value at 50, then press
Enter. The screen returns to the Tank Levels tab screen
with '50' displayed in the 'Low Tank Volume (L)'
display.
To Set the Low Tank Alarm:
Press the 'Low Tank Alarm' touch button to select or
deselect the alarm.
GA8701177 REV 2 APRIL 2022
Press the Tank Levels Tab touch button to open the Tank Calibration screen.
The touch button displays Green when selected & Grey
when deselected.
D. Tank Calibration Tab
Press the Tank Calibration Tab touch button to open the Tank
Calibration settings screen and the Tank Calibration screen
opens displaying:
i)
Product Tank Calibration
(NOT CURRENTLY IN USE)
ii) Product Tank Volume
iii) Rinse Tank Calibration.
The Tank Calibration screen is locked for protection from
uninformed or accidental alteration.
The screen must be unlocked before any setting or alterations
can be made. Refer to previous pages for the details to unlock
the screen.
ii) Product Tank Volume
The Product Tank Volume settings comprise:
'Product Tank Sensor Reading (mA)' - is the current
value of the product tank pressure transducer sensor.
This will vary depending on volume between 4000 &
20000.
'Empty Set Point' - is the value of the product tank
Setting Up – Preparation for Use
Press the 'Empty Set Point' display touch button to enter the value, OR
press 'Set' when the product tank is empty.
pressure transducer sensor when the tank is empty.
This will offset the tank calibration values if changed.
To Set the Empty Set Point:
1 Press the 'Low Tank Volume (L)' display touch button
and a numerical keypad appears.
2 Press the numbers to set the value between 4000 &
20000, then press Enter. The screen returns to the Tank
Calibration tab screen with eg, 4200 displayed in the
'Empty Set Point' display.
OR
4
79