PROBLEM
COMMON CAUSES
Incorrect console
calibration
Inconsistent ground
speed reading
Application rate is
Inconsistent flow
inaccurate, unstable
meter reading
or zero
Faulty control valve
Speed sensor
Incorrect speed
display is inaccurate,
calibration
unstable or zero
Meter calibration is
incorrect
Flow meter cable pins
Volume display is
are corroded
inaccurate, unstable,
zero or not changing
Flow meter is pointing
the wrong way
Faulty cable
Flow meter is seized
or blocked
Flow meter appears
Faulty cable
not to be working
Calibration figure is
incorrect
Application rate or
Faulty control valve
pressure will not alter
Faulty cable
Control valve has
failed
Faulty valve
GA8701177 REV 2 APRIL 2022
COMMON SOLUTION
Re-calibrate console
Check cabling
Replace flow meter
Replace control valve
Check using manual increase/decrease flow
control
Re-calibrate console speed
Reset meter calibration
Replace flow meter plugs & pins
Disconnect flow meter and reinstall in the
correct orientation
Manually test the cable
Remove and clean any foreign materials so
the turbine spins freely
Test cable as per instructions following
Reset meter calibration
Test valve manually and replace if required
Replace control valve
Temporary solutions:
Remove the motor from the 3 way ball valve
and manually adjust the flow by turning the
shaft with a spanner
Trouble Shooting – Fast Tracking Problems
If the flow meter fails to give accurate readings, the following actions should be taken:
• Adjust the spraying pressure by putting the flow control switch into manual and using the
increase decrease switch to adjust to the desired pressure as shown on the pressure
gauge on the machine.
• Drive the machine at a constant speed in order to apply the required application volume as
determined by the nozzle selection chart.
• The machine should then be operated to empty the tank. Once the machine is empty of
chemical, partially fill the tank with fresh water so that test can be performed in order to
correct the problem. Repair or replace the flow meter as soon as possible.
Spray Nozzles
PROBLEM
COMMON CAUSES
Nozzle tip blockages.
Streaky pattern
coming from nozzle
Nozzle worn or damaged.
Nozzle tip blockages.
No spray coming
from nozzle
Check valve blockages.
9
COMMON SOLUTION
Check for blockages by removing the
nozzle, rinsing thoroughly with water and
cleaning with compressed air.
DO NOT clean by blowing into nozzle
with mouth.
Visually inspect nozzle for damage or
wear, conduct a jug test if necessary.
Check for blockages by removing the
nozzle, rinsing thoroughly with water and
cleaning with compressed air.
Remove the check valve and clean as
required.