Preparation for Use – Setting Up
4
Press the 'Alarm?' touch button to enable the Alarms. Press the
Help Menu '?' touch button for Alarm setting notes. Press 'Next'.
38 Press the 'Alarms' touch button to enable
the Alarms.
A 'Tick" appears when Enabled (the
checkbox is blank when Disabled).
39 Press the Help Menu '?' touch button to
read notes on Alarm settings.
40 Press the 'Next' touch button and
a 'Setup Auxiliary Functions' screen
appears.
41 In the Setup Auxiliary Function panel:
Leave the 'Agitator Installed' box blank
as agitator is controlled by the G-Hub.
Press the 'Flow Return Installed' box
to select the Flow Return Installed. A
"Tick" appears when Selected (the box
is blank when unselected).
HELP MENU INFORMATION
Minimum Pressure
Enter the minimum desired pressure for the system while
applying.
When the pressure sensor is assigned to a liquid product,
the alarm is enabled and the minimum pressure threshold
has been met, the rate controller will override flow control
and attempt to maintain the minimum pressure setting.
This condition may result in over-application.
70
Press & 'Tick' the 'Flow Return Installed' box as shown.
Press the 'Next' touch button.
This stops the 'Warning Pop-Up' when the
boom RapidFlow is On (Automatic mode).
If using Manual Mode, an operator may
choose to leave this box unchecked to be
reminded of switching Off the RapidFlow
for spraying.
42 Press the 'Next' touch button and a
'Setup Tiered Boom' screen appears.
This screen requires the operator to
calculate the maximum flow rates of
nozzles fitted to Tier 1 & Tier 2 boom
sections.
Refer to Chapter 6 'Calibration' for
the information required to determine
Maximum Tier Flow Rates & Nozzle
Charts.
HELP MENU INFORMATION
Maximum Pressure
Enter the maximum desired pressure for the system while
applying.
When the pressure sensor is assigned to a liquid product,
the alarm is enabled and the maximum pressure threshold
has been met, the rate controller will override flow control
and attempt to maintain the maximum pressure setting.
This condition may result in under-application.
Press the 'Tier 1' & 'Tier 2' touch buttons to enter the
appropriate Tier Maximum Flow Rates.
43 Press the 'Tier 1 Max Flow Rate' touch
button and a keypad appears. Press
the touch buttons to set the minimum
pressure value eg '50' (L/min), then press
the 'Tick' touch button.
The 'Setup Tiered Boom' screen returns
with eg '50' (L/min) displayed in the 'Tier 1
Max Flow Rate' display.
44 Press the 'Tier 2 Max Flow Rate' touch
button and a keypad appears. Press
the touch buttons to set the minimum
pressure value eg, '90' (L/min), then press
the 'Tick' touch button.
The 'Setup Tiered Boom' screen returns
with eg, '90' (L/min) showing in the 'Tier 2
Max Flow Rate' display (example only).
Valve Response Rate
The Response Rate has a range of 1 to 100 and the
setting determines how aggressively the target rate is
controlled to. Increasing this value will cause the system
to respond more quickly. Decreasing it will cause a slower
response. If the flow is slow to reach the target value,
consider increasing it.
Press the 'Percent Tier Disable' touch button and enter
10% as shown, then press the 'Next' touch button.
45 Press the 'Percent Tier Disable' touch
button and a keypad appears. Press the
touch buttons to set the value eg, '10' (%),
then press the 'Tick' touch button.
The 'Setup Tiered Boom' screen returns
with eg, '10' (%) showing in the 'Percent
Tier Disable' display.
Max Flow Rates & Tier Disable values will
vary with nozzle type selected.
46 Press the 'Next' touch button and and a
'Setup Control Valve' screen appears.
Percent Tier Disable
The 'Percent Tier Disable' value is usd to minimise
unnecessary tier switching when spraying close to the
switch point of a tier. Increasing the value, reduces the
sensitivity when switching tiers.
The '10% Percent Tier Disable' value means a spraying
Tier will not change down until the spray rate is 10% below
the target rate.
GA8701177 REV 2 APRIL 2022