Sections are numbered 1 to16 starting from the left hand side. Dotted vertical lines illustrate Centreline (rowcrop) plumbing nozzle locations. Solid vertical lines illustrate the broadacre plumbing nozzle location option.
Left boom end
Section 1
Section 2
Section 3
4 x 500
4 x 500
5 x 500
=
=
=
2.0m
2.0m
2.5m
68
Section Details of a 36m Boom with Broadacre
Plumbing
Section
Nozzle
No Nozzles
Number
Spacing
in Section
(L to R)
(m)
1
0.5
4
2
0.5
4
3
0.5
5
4
0.5
5
5
0.5
4
6
0.5
4
7
0.5
5
8
0.5
5
9
0.5
5
10
0.5
5
11
0.5
4
12
0.5
4
13
0.5
5
14
0.5
5
15
0.5
4
16
0.5
4
Total No of nozzles:
72
Spray Application Width:
An illustration of a 36m Centreline (rowcrop) plumbed boom showing the details of the 16 boom sections.
Section 4
Section 5
Section 6
Section 7
5 x 500
4 x 500
4 x 500
5 x 500
=
=
=
=
2.5m
2.0m
2.0m
2.5m
Section
Width
(m)
2.0
2.0
2.5
2.5
2.0
Individually press each 'Section' touch button from 1st to
2.0
16th & set each width in metres.
2.5
25 Individually press each 'Section Width'
2.5
touch button and a numerical keypad
appears.
2.5
2.5
2.0
2.0
2.5
2.5
2.0
2.0
36.0m
Section 8
Section 9
Section 10
5 x 500
6 x 500
5 x 500
=
=
=
2.5m
3.0m
2.5m
Press touch buttons to enter the section width, then pres