The Suction Filter shown with a centrifugal pump.
Suction Filter Removal & Cleaning
It is recommended to remove & clean the Suction Filter
regularly - before each tank fill. Frequency of cleaning will
depend on the quality of water and chemicals used
The Suction Filter receives liquid from either the Product Tank.
or the Rinse Tank. All liquid to be sprayed or flushed through
the system passes through this filter.
Fluid supply to the suction filter is controlled by an electronically
operated valve. The valve operation is controlled by the presets
in the G-Hub controller (refer to Chapter 4).
The suction filter valve is plumbed before the filter housing
When rinsing is taking place, the rinsate is potentially very hazardous depending
on chemical content.
Use recommended personal protective equipment (PPE).
For specific information on rinsing & decontamination of the chemicals being
applied, it is recommended to consult the chemical manufacturer's label and/or
your chemical supplier.
GA8701177 REV 2 APRIL 2022
Open the drain valve to drain the Suction Filter.
To Remove & Clean the Suction Filter:
1 Make sure the 'Pump Product push button is Off.
2 Open the drain valve on the filter & allow the filter to
drain fully.
Be sure to collect any hazardous chemical and wear
appropriate PPE.
3 Close the drain and loosen the filter bowl collar slowly using
the spanner provided. Be aware some residual chemical
may dribble out.
4 After liquid stops flowing from the filter, fully unscrew the
filter bowl collar and remove the filter bowl.
Be careful not to damage the O-Rings.
Unscrew the filter bowl collar to remove the filter bowl.
Operation – Ready to Spray
Remove the Suction Filter screen.
5 After removing the filter bowl, carefully remove the filter
screen, then clean the filter bowl, body, screen & O-rings.
6 After cleaning, refit the components making sure the filter
bowl & O-rings are correctly placed.
7 Fully tighten the filter bowl collar & close the drain valve.
Fully tighten the filter bowl collar & close the drain valve.
6