Goldacres G6 Crop Cruiser 2 Series Operator's Manual page 94

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

Set & Check Application Rates – Calibration
5
An illustration of the speed range & output (70l/ha) available of two nozzles fitted
with the 3TS Option.
3TS Option
Find two nozzles which are nearest to the application
requirements..
Check the speed variation available maintaining the same
application rate & droplet size.
It is recommended to select two nozzles which allow the spray
controller to adjust pressure & switch nozzles On & Off with
required speed variations while maintaining consistent droplet
size and application rate.
Using the appropriate nozzle chart, look down the nozzle
capacity column (l/min) and select a nozzle to suit the output
(eg 0.8 l/min), droplet size and travel speed.
Refer to the commonly used Teejet and Lechler broadacre
nozzle charts at the end of this chapter. For more information,
go to:
www.teejet.com
www.lechler.com
Download the free copy of 'A user's guide to spray nozzles' from the TeeJet
website. Also Lechler nozzle selection catalogue and Users guides to spray
nozzles are available from your Goldacres dealer, or as a free download from the
TeeJet web site: www.teejet.com or Lechler web site: www.lechler.de
94
AIXR APPLICATION CHART
CAPACITY
DROP
LERAP
ONE NOZZLE
SIZE
RATINGS
5
6
bar
IN L/MIN
km/h
km/h
XC
1.0
0.34
81.6
68.0
2.0
C
0.48
115
96.0
AIXR110015
3.0
C
0.59
142
118
4.0
M
0.68
163
136
(100)
5.0
M
0.76
182
152
6.0
0.83
199
166
M
1.0
XC
0.46
110
92.0
2.0
VC
0.65
156
130
AIXR11002
3.0
C
0.79
190
158
4.0
M
0.91
218
182
(50)
5.0
M
1.02
245
204
6.0
M
1.12
269
224
1.0
XC
**
0.57
137
114
2.0
VC
**
0.81
194
162
AIXR110025
3.0
VC
**
0.99
238
198
4.0
C
**
1.14
274
228
(50)
5.0
C
**
1.28
307
256
6.0
M
1.40
336
280
1.0
XC
**
0.68
163
136
The 1st AXIR110015 nozzle @ 2 Bar gives 0.48l/min & an output of 0.68l/min @ 4 Bar
2.0
VC
**
0.96
230
192
& 2nd AXIR11002 nozzle @ 3 Bar gives 0.79l/min & an output of 1.02l/min @ 5 Bar.
AIXR11003
3.0
VC
**
1.18
283
236
4.0
C
**
1.36
326
272
(50)
5.0
C
**
1.52
365
304
6.0
M
1.67
401
334
1.0
UC
***
0.91
218
182
Example: Nozzle Selection for the 3TS Option
2.0
XC
**
1.29
310
258
AIXR11004
3.0
VC
**
1.58
379
316
Using the AIXR Teejet Application Chart:
4.0
VC
**
1.82
437
364
(50)
5.0
C
**
2.04
490
408
6.0
C
2.23
535
446
Look down the nozzle capacity column (l/min) and select two
UC
1.0
***
1.14
274
228
nozzles to suit an output of 0.8 l/min (shown above).
2.0
XC
***
1.61
386
322
AIXR11005
3.0
VC
**
1.97
473
394
(50)
4.0
VC
**
2.27
545
454
The AXIR110015 nozzle @ 2 Bar gives 0.48l/min which is 82.3
5.0
C
**
2.54
610
508
l/ha at 7 kmh and an output of 0.68l/min @ 4 Bar which is 81.6
6.0
C
2.79
670
558
1.0
UC
***
1.37
329
274
l/ha at 10 kmh.
2.0
XC
***
1.94
466
388
AIXR11006
3.0
VC
***
2.37
569
474
The AXIR11002 nozzle @ 2 Bar gives 0.65l/min which is 78.0 l/
4.0
VC
**
2.74
658
548
(50)
5.0
C
**
3.06
734
612
ha at 10 kmh and an output of 1.02l/min @ 5 Bar which is 76.5
6.0
C
3.35
804
670
1.0
UC
1.82
437
364
l/ha at 16 kmh.
2.0
XC
2.58
619
516
AIXR11008
3.0
VC
3.16
758
632
These nozzles should allow the controller to apply 80 litres per
4.0
VC
3.65
876
730
(50)
5.0
VC
4.08
979
816
ha with a speed range of 7 to 16 kmh and a pressure range of
6.0
C
4.47
1073
894
1.0
UC
2.28
547
456
2 to 5 Bar switching between the 1st & 2nd Tiers.
2.0
UC
3.23
775
646
3.0
XC
3.95
948
790
AIXR11010
By adding these two outputs together to use the 3rd Tier @ 3-4
4.0
VC
4.56
1094
912
5.0
VC
5.10
1224
1020
Bar to give 1.38 -1.59 l/min would provide 80 l/ha application
6.0
VC
5.59
1342
1118
NOTE: Always double check your application rates. Tabulations are based on spraying water at 21°C.
rate at increased speeds of 20 to 22kmh.
Fit the selected nozzles to the boom.
DROPLET SIZE CATEGORIES
XF
VF
F
M
EXTREMELY
VERY
FINE
MEDIUM
FINE
FINE
When selecting nozzle outputs, higher pressures & wider spray angles generally
Droplet size may vary with nozzle capacity, spray angle and spray pressure.
give finer droplet sizes than lower pressures & narrower spray angles.
l/ha
50 cm
CAP PART
NUMBER
7
8
10
12
16
18
20
km/h
km/h
km/h
km/h
km/h
km/h
km/h
58.3
51.0
40.8
34.0
25.5
22.7
20.4
82.3
72.0
57.6
48.0
36.0
32.0
28.8
101
88.5
70.8
59.0
44.3
39.3
35.4
117
102
81.6
68.0
51.0
45.3
40.8
130
114
91.2
76.0
57.0
50.7
45.6
142
125
99.6
83.0
62.3
55.3
49.8
78.9
69.0
55.2
46.0
34.5
30.7
27.6
111
97.5
78.0
65.0
48.8
43.3
39.0
135
119
94.8
79.0
59.3
52.7
47.4
156
137
109
91.0
68.3
60.7
54.6
175
153
122
102
76.5
68.0
61.2
192
168
134
112
84.0
74.7
67.2
97.7
85.5
68.4
57.0
42.8
38.0
34.2
139
122
97.2
81.0
60.8
54.0
48.6
170
149
119
99.0
74.3
66.0
59.4
195
171
137
114
85.5
76.0
68.4
219
192
154
128
96.0
85.3
76.8
240
210
168
140
105
93.3
84.0
117
102
81.6
68.0
51.0
45.3
40.8
165
144
115
96.0
72.0
64.0
57.6
202
177
142
118
88.5
78.7
70.8
233
204
163
136
102
90.7
81.6
261
228
182
152
114
101
3TS Pro Option
91.2
286
251
200
167
125
111
100
156
137
109
91.0
68.3
60.7
54.6
Find three nozzles nearest to the requirements.
221
194
155
129
96.8
86.0
77.4
271
237
190
158
119
105
94.8
Check the required speed variations are available maintaining
312
273
218
182
137
121
109
350
306
245
204
153
136
122
the same application rate & droplet size.
382
335
268
223
167
149
134
195
171
137
114
85.5
76.0
68.4
It is recommended to select three nozzles which allow the
276
242
193
161
121
107
96.6
338
296
236
197
148
131
118
spray controller to adjust pressure & switch nozzles On & Off
389
341
272
227
170
151
136
435
381
305
254
191
169
152
with the required speed variations while maintaining consistent
478
419
335
279
209
186
167
235
206
164
137
103
91.3
droplet size and application rate.
82.2
333
291
233
194
146
129
116
406
356
284
237
178
158
142
Using the appropriate nozzle chart, look down the nozzle
470
411
329
274
206
183
164
525
459
367
306
230
204
capacity column (l/min) and select a nozzle to suit the output
184
574
503
402
335
251
223
201
(eg 0.8 l/min), droplet size and travel speed.
312
273
218
182
137
121
109
442
387
310
258
194
172
155
542
474
379
316
237
211
190
Refer to the most commonly used Teejet and Lechler
626
548
438
365
274
243
219
broadacre nozzle charts at the end of this chapter.
699
612
490
408
306
272
245
766
671
536
447
335
298
268
391
342
274
228
171
152
137
554
485
388
323
242
215
194
677
593
474
395
296
263
237
782
684
547
456
342
304
274
874
765
612
510
383
340
306
958
839
671
559
419
373
335
C
VC
XC
UC
COARSE
VERY
EXTREMELY
ULTRA
COARSE
COARSE
COARSE
Calculation is required to ensure spraying pressures do not exceed operating
parameters.
|
13
teejet.com
GA8701177 REV 2 APRIL 2022

Advertisement

Table of Contents
loading

Table of Contents