Goldacres G6 Crop Cruiser 2 Series Operator's Manual page 147

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

Process all rinse functions of the 'Clean' screen, individually using the Select &
Start/Stop push buttons.
14 Process each Rinse function of the list on the External
Controller 'Clean' screen:
Pressure Filter
RapidFlow - Open Gauge Flush
Bypass Valve
Agitator
Deadhead Pump (diaphragm pump only)
Hopper
Main Tank Fill Line
Tank Rinse from Pump
Tank Rinse from Fill
Main Tank Suction Line - Only do this if the tank is
empty. The pump must be off & suction filter drain open.
Individually use the push buttons to:
Select
Start - allowing each function suitable time to rinse
thoroughly, then
Stop the function.
Several functions can be started & running together but
then stopped individually with the Start/Stop push button.
GA8701177 REV 2 APRIL 2022
Open (shown left) and Closed (shown right) the Spray Gauge valve to
decontaminate & flush the line.
15 Open & Close the Spray Gauge valve to decontaminate &
flush out any chemical.
18 After decontaminating the whole system, proceed to the
next step of flushing the system with fresh water.
After Total Rinse & Decontamination, it is recommended to remove and clean the
pressure filter and the suction filter.
Both filters should be cleaned regularly.
Operation – Ready to Spray
Flush the Spray System with Clean Water
Repeat the Basic Rinse process to flush the Spray System with
clean water (after total cleaning and contamination has been
performed) to remove any remaining Rinsate and boom cleaner.
Dispose of chemical & pesticide waste safely.
If possible, reuse the rinsate when preparing the next batch of tank mixture. Make
sure all the dirt and debris in the rinsate are filtered out before adding the rinsate
to a spray tank. Small amounts of solids left should be dried, then taken to a
hazardous waste disposal site or pesticide collection location.