Test Actual Sprayer Output - Goldacres G6 Crop Cruiser 2 Series Operator's Manual

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

Press the 'Tick' touch button.
The screen returns to the Tiered Boom Setup screen with
'92.2' displayed in the Tier 3 Max Flow Rate value.
5 Press the 'Tick' touch button and the screen returns to the
System Setting screen.
This completes the controller entries for the 3TS Pro Option
boom calibration.
GA8701177 REV 2 APRIL 2022
Calibration – Set & Check Application Rates
Nozzle by nozzle turn compensation with the Hawkeye option.
d) Hawkeye Option (Nozzle Control System)
The Hawkeye Pulse Width Modulated (PWM) technology is an
available option.
Hawkeye 2.0 is offered on 36m and 48m booms with nozzle
spacing at 250mm & 500mm providing:
Nozzle by nozzle turn compensation with each nozzle
featuring its own microprocessor & perform diagnostic
functions.
Up to 16 virtual sections & individual nozzle control.
For instructions on configuring & operating the Hawkeye, refer
to the Raven Hawkeye Operation Manual supplied.
Unfold the boom in a suitable area & set the height of the boom to allow easy
access to nozzles.

5 Test Actual Sprayer Output

Testing the Actual Sprayer Output to ensure the accuracy of
the application rate before spraying is essential.
This part of calibration uses the 'Jug Test' to check spray
nozzles deliver the correct amount of liquid, according to the
nozzle manufacturer's rate chart.
Jug Test
Items required for the 'Jug Test' are:
Calibrated 2 litre measuring jug which measures in no
less than 10 ml increments
Timing device that counts in seconds
Device or pen & paper for recording nozzle outputs
Pressure gauge mounted on a nozzle tip to verify
pressure being delivered at the nozzle.
Goldacres part number GA5077983 (suitable gauge mount) is
available for attaching a gauge to nozzle body bayonet fittings
(gauge not included).
Do not proceed with nozzle testing with mixed chemicals, pesticides or an
uncleaned liquid system. Ensure the liquid system is completely decontaminated
and use only clean water for testing.
Contamination or use of any chemicals or pesticides when testing is extremely
hazardous to human health.
5
99