Ready to Spray – Operation
6
Open the Mixing Jet valve on the RHS of the Hopper.
4 Add the required chemical granules or
powder into the flowing liquid.
5 Open the Mixing Jet valve on the right
hand side of the hopper to start mixing.
If required turn On the mixing jet to assist
induction.
Add the chemical granules or powder to the flowing liquid.
130
On completion of mixing, Close the Mixing Jet valve.
6 Open the foot operated 3" ball valve at the
base of the Hopper to transfer product
into the Main Tank.
8 Rinse all chemicals from the Induction
Hopper (refer to instructions in this
Chapter 'Hopper Rinse Functions')
When transfering contents of the hopper to the Product
Tank, avoid letting the hopper run empty or suck air
because it may cause foaming in the Product Tank.
Lift-up to Close the foot operated ball valve at the bottom
of the hopper.
To Transfer Chemical to the Product
Tank using the Bottom Drain Valve
The Bottom Drain Valve can be used for
Chemical Induction.
1 Lift up the lever to Close the foot operated
ball valve at the bottom of the hopper.
2 Close the Bottom Ball Valve & remove the
camlock coupling.
3 Connect a micromatic hose to the Bottom
Ball Valve camlock coupling.
Close the Bottom Drain valve & remove the camlock
coupling plug.
Press the 'Pump Product' push button On & the 'Hopper'
push button On.
4 Press the 'Hopper' push button On to
engage the Product Pump & Hopper
valve. This push button automatically
raises engine RPM.
5 Press the 'Pump Product' push button On
to engage suction from Product tank.
The pump should operate at the speed
necessary to generate at least 80 psi
delivery pressure (with hopper On) delivery
pressure (displayed on the External G-Hub
Controller screen).