Controller Set-Up - Goldacres G6 Crop Cruiser 2 Series Operator's Manual

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

AIXR APPLICATION CHART
CAPACITY
DROP
LERAP
ONE NOZZLE
SIZE
RATINGS
5
6
bar
IN L/MIN
km/h
km/h
XC
1.0
0.34
81.6
68.0
2.0
C
0.48
115
96.0
AIXR110015
3.0
C
0.59
142
118
4.0
M
0.68
163
136
(100)
5.0
M
0.76
182
152
6.0
0.83
199
166
M
1.0
XC
0.46
110
92.0
2.0
VC
0.65
156
130
AIXR11002
3.0
C
0.79
190
158
4.0
M
0.91
218
182
(50)
5.0
M
1.02
245
204
6.0
M
1.12
269
224
1.0
XC
**
0.57
137
114
2.0
VC
**
0.81
194
162
AIXR110025
3.0
VC
**
0.99
238
198
4.0
C
**
1.14
274
228
(50)
5.0
C
**
1.28
307
256
6.0
M
1.40
336
280
1.0
XC
**
0.68
163
136
The 3TS Pro option requires three nozzles to be selected giving the operator a greater
2.0
VC
**
0.96
230
192
AIXR11003
range of application rates and travel speeds.
3.0
VC
**
1.18
283
236
4.0
C
**
1.36
326
272
(50)
Example: Nozzle Selection for the 3TS Pro Option
5.0
C
**
1.52
365
304
6.0
M
1.67
401
334
1.0
UC
***
0.91
218
182
Using the AIXR Teejet Application Chart:
2.0
XC
**
1.29
310
258
AIXR11004
3.0
VC
**
1.58
379
316
Look down the nozzle capacity column (l/min) and select two
4.0
VC
**
1.82
437
364
(50)
5.0
C
**
2.04
490
408
nozzles to suit an output of 0.8 l/min (shown above).
6.0
C
2.23
535
446
UC
1.0
***
1.14
274
228
The AXIR110015 nozzle @ 2 Bar gives 0.48l/min which is 82.3
2.0
XC
***
1.61
386
322
AIXR11005
3.0
VC
**
1.97
473
394
l/ha at 7 kmh and an output of 0.68l/min @ 4 Bar which is 81.6
(50)
4.0
VC
**
2.27
545
454
5.0
C
**
2.54
610
508
l/ha at 10 kmh.
6.0
C
2.79
670
558
1.0
UC
***
1.37
329
274
The AXIR11002 nozzle @ 2 Bar gives 0.65l/min which is 78.0 l/
2.0
XC
***
1.94
466
388
AIXR11006
3.0
VC
***
2.37
569
474
ha at 10 kmh and an output of 1.02l/min @ 5 Bar which is 76.5
4.0
VC
**
2.74
658
548
(50)
l/ha at 16 kmh.
5.0
C
**
3.06
734
612
6.0
C
3.35
804
670
1.0
UC
1.82
437
364
The AXIR110025 nozzle @ 2 Bar gives 0.81l/min which is 81.0
2.0
XC
2.58
619
516
l/ha at 12 kmh and an output of 1.28l/min @ 5 Bar which is
AIXR11008
3.0
VC
3.16
758
632
4.0
VC
3.65
876
730
(50)
76.8 l/ha at 20 kmh.
5.0
VC
4.08
979
816
6.0
C
4.47
1073
894
1.0
UC
2.28
547
456
These nozzles should allow the controller to apply 80 litres per
2.0
UC
3.23
775
646
ha at speeds ranging from 7 up to 40 kmh
3.0
XC
3.95
948
790
AIXR11010
4.0
VC
4.56
1094
912
5.0
VC
5.10
1224
1020
Fit the selected nozzle to the boom.
6.0
VC
5.59
1342
1118
NOTE: Always double check your application rates. Tabulations are based on spraying water at 21°C.
DROPLET SIZE CATEGORIES
XF
VF
F
M
EXTREMELY
VERY
FINE
MEDIUM
FINE
FINE
There are often very serious limitation to possible maximum spray speeds.
Droplet size may vary with nozzle capacity, spray angle and spray pressure.
Maximum spray speeds are limited by safety factors, chemicals used, maximum
boom output in l/min, type of target, field conditions, terrrain and weather
conditions.
GA8701177 REV 2 APRIL 2022
l/ha
50 cm
CAP PART
NUMBER
7
8
10
12
16
18
20
km/h
km/h
km/h
km/h
km/h
km/h
km/h
58.3
51.0
40.8
34.0
25.5
22.7
20.4
82.3
72.0
57.6
48.0
36.0
32.0
28.8
101
88.5
70.8
59.0
44.3
39.3
35.4
117
102
81.6
68.0
51.0
45.3
40.8
130
114
91.2
76.0
57.0
50.7
45.6
142
125
99.6
83.0
62.3
55.3
49.8
78.9
69.0
55.2
46.0
34.5
30.7
27.6
111
97.5
78.0
65.0
48.8
43.3
39.0
135
119
94.8
79.0
59.3
52.7
47.4
156
137
109
91.0
68.3
60.7
54.6
175
153
122
102
76.5
68.0
61.2
192
168
134
112
84.0
74.7
67.2
97.7
85.5
68.4
57.0
42.8
38.0
34.2
139
122
97.2
81.0
60.8
54.0
48.6
170
149
119
99.0
74.3
66.0
59.4
195
171
137
114
85.5
76.0
68.4
219
192
154
128
96.0
85.3
76.8
240
210
168
140
105
93.3
84.0
117
102
81.6
68.0
51.0
45.3
40.8
165
144
115
96.0
72.0
64.0
57.6
202
177
142
118
88.5
78.7
70.8
233
204
163
136
102
90.7
81.6
261
228
182
152
114
101
Hawkeye Option (Nozzle Control System)
91.2
286
251
200
167
125
111
100
156
137
109
91.0
68.3
60.7
54.6
The Hawkeye Pulse Width Modulated (PWM) technology is an
221
194
155
129
96.8
86.0
77.4
271
237
190
158
119
105
94.8
available option. If fitted refer to the manufacturer's manual.
312
273
218
182
137
121
109
350
306
245
204
153
136
122
382
335
268
223
167
149
134
195
171
137
114
85.5
76.0
68.4
276
242
193
161
121
107
96.6
338
296
236
197
148
131
118
389
341
272
227
170
151
136
435
381
305
254
191
169
152
478
419
335
279
209
186
167
235
206
164
137
103
91.3
82.2
333
291
233
194
146
129
116
406
356
284
237
178
158
142
470
411
329
274
206
183
164
525
459
367
306
230
204
184
574
503
402
335
251
223
201
312
273
218
182
137
121
109
442
387
310
258
194
172
155
542
474
379
316
237
211
190
626
548
438
365
274
243
219
699
612
490
408
306
272
245
766
671
536
447
335
298
268
391
342
274
228
171
152
137
554
485
388
323
242
215
194
677
593
474
395
296
263
237
782
684
547
456
342
304
274
874
765
612
510
383
340
306
958
839
671
559
419
373
335
C
VC
XC
UC
COARSE
VERY
EXTREMELY
ULTRA
COARSE
COARSE
COARSE
|
13
teejet.com
Calibration – Set & Check Application Rates
Opening Warning screen of the optional Raven CR7.

4 Controller Set-Up

New application rate values must be entered into Automatic
Control Module (RCM) according to the boom's nozzle
configuration.
The Cruiser may be fitted with one of four nozzle control option
technologies:
a) Single line boom
b) 3TS option
c) 3TS Pro option
d) Hawkeye option (nozzle control system).
a) Enter Values for the Single Line Boom
After nozzle selection, a single line boom configuration requires
the application rates to be entered into the controller according
to the nozzle selected.
To Enter New Values:
1 Start the engine.
2
"WARNING DO NOT OPERATE ON ROADWAYS OR NEAR
appears on the optional Raven CR7 screen or
OBSTACLES"
ISO bus screen.
Press the OK button and the home screen appears.
5
95

Advertisement

Table of Contents
loading

Table of Contents