Goldacres G6 Crop Cruiser 2 Series Operator's Manual page 72

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

Preparation for Use – Setting Up
4
Press the 'Tank Capacity' touch button. Press the 'Low
Tank Level' touch button. Enable the Alarm. Press 'Next'.
55 The 'Tank Fill/Level Sensor' should display
'None'.
56 Press the 'Tank Capacity' touch button
and a keypad appears. Press the touch
buttons to enter the total tank volume
in litres eg, '6000', then press the 'Tick'
touch button.
The 'Setup Tank/Bin' screen returns with
eg, '6000' displayed in 'Tank Capacity'.
Actual tank volume may be more eg, 6200
& may be used if desired.
57 Press the 'Low Tank Level' touch button
and a keypad appears. Press the touch
buttons to enter the total tank volume in
litres '300', then press the 'Tick touch
button.
The 'Setup Tank/Bin' screen returns with
'300' displayed in the 'Low Tank Level'.
58 Press the 'Low Tank Level Alarm'
checkbox to enable the Alarm. A 'Tick'
appears when the Alarm is enabled (the
checkbox is blank if disabled).
59 Press the 'Next' touch button and a
'Setup Rates' screen appears.
72
Press 'Preset Rate Values' touch button and set the rate
required, then set the 'Rate Bump' value.
60 Press the 'Preset Rate Values - Rate 1'
touch button and a keypad appears.
Press the touch buttons to enter the rate
required in litres, eg. '50' (L/ha), then press
the 'Tick' touch button.
The 'Setup Tank/Bin' screen returns with
'50' displayed in 'Tank Capacity'.
61 Repeat for rates required in 'Rate 2' and
'Rate 3'
62 Press the 'Rate Bump' touch button and a
keypad appears. Press the touch buttons
to enter the rate value, eg '5', then press
the 'Tick' touch button.
The 'Setup Rates' screen returns with '5'
displayed in 'Rate Bump'.
Rate Bump
When spraying in Manual Mode, the operator can adjust
the Spray Application Rate (using touch buttons on the
Controller) by the amount (l/ha) pre-set in the Spray Bump
setting.
Press 'Rate Selection' touch button & select 'Predefined or
Rx' Smoothing'.
64 Press the 'Rate Selection' touch button
and a menu appears. Select & press
'Predefined or Rx'.
The 'Setup Rates' screen returns with
'Predefined or Rx' displayed.
Press the 'Rate Selection' touch button & select the
'Predefined or Rx' setting. Press the 'Next' touch button.
Press the 'Enable 'Display Smoothing' checkbox, then. Set
the 'Decimal Shift' value. Press the 'Next' touch button.
65 Press the 'Display Smoothing' checkbox
to enable display smoothing. A 'Tick'
appears when the 'Display Smoothing' is
enabled (the checkbox is blank if disabled).
64 Press the 'Decimal Shift' touch button and
a menu appears. Select & press '1'.
The 'Setup Rates' screen returns with '1'
displayed in decimal shift.
65 Press the 'Next' touch button and a
'Setup Alarms' screen appears.
GA8701177 REV 2 APRIL 2022

Advertisement

Table of Contents
loading

Table of Contents