Adding Chemicals To The Product Tank; Chemical Induction Hopper - Goldacres G6 Crop Cruiser 2 Series Operator's Manual

Hide thumbs Also See for G6 Crop Cruiser 2 Series:
Table of Contents

Advertisement

The external G-Hub Controller located in the storage
cabinet of the Quick Filling Station.
Adding Chemicals to the
Product Tank
Chemicals are added to the Product Tank
using the:
Chemical Induction Hopper (granular &
liquid)
Chemical Probe (liquid only).
Before adding chemical to the Product tank,
at least 500 litres of clean water must be in the
Product Tank - required to ensure the Product
Pump operates to create the venturi effect
required for transfer fluid from the Chemical
Induction Hopper to the Product Tank and to
ensure adequate agitation when chemical is
added.
All functions for adding chemicals require the
Cruiser to be safely parked in an appropriate
area with the engine running.
Wear the necessary protective clothing and use the
required safety equipment to avoid exposure to chemicals.
GA8701177 REV 2 APRIL 2022
Remove the hopper safety pin & locking pin.

Chemical Induction Hopper

The Chemical Induction Hopper provides
mixing, measuring and induction functions
for adding required chemicals to the Product
Tank.
The Bottom Drain Valve can be used as an
entry point for Chemical Induction directly to the
Product Tank.
To Lower the Chemical Induction Hopper
1 Remove the safety pin, then the locking
pin from the hopper lifting arms.
Support the hopper weight & lift the lever to unlock the
holding latch & lower the hopper.
Operation – Ready to Spray
Pull the hopper down into its working position.
2 Support the weight of the hopper, then pull
the latch lever beside the hopper to unlock
the latch holding the hopper in position.
3 Pull down the hopper slowly to its work
position.
4 Check the hoses connecting to the hopper
are not restricted or kinked.
With hopper in working position, check hoses are not
restricted or kinked.
Undo the latch & open the Hopper lid.
To Add & Mix Chemical in the Chemical
Induction Hopper
1 Undo the latch & open the Hopper lid.
2 Press the 'Pump Product' push button On
to engage suction from Product tank.
The pump should operate at the speed
necessary to generate at least 80 psi (with
hopper On) delivery pressure (displayed on
the External G-Hub Controller screen).
3 Press the 'Hopper' push button On to
engage the Product Pump & Hopper
valve. This push button automatically
raises engine RPM.
Press the 'Pump Product' push button On & the 'Hopper'
push button On.
6
129

Advertisement

Table of Contents
loading

Table of Contents