Total Rinse & Decontamination
Total Rinse & Decontamination of the Cruiser's spraying system
is important whenever changing chemicals or applications and
at the end of the spraying application.
Total Rinse & Decontamination draws clean water from an
external source using the Fill Pump & 3" clean water inlet, plus
an appropriate cleaner/decontaminant is added to clean &
neutralise the chemicals previously used.
The procedure requires a minimum of 1000 litres of clean water
in the Product Tank and the Rinse Tank must be filled before
proceeding.
After Rinsing, it is recommended to remove and clean the pressure filter and the
suction filter.
146
Press the 'Pump Rinse', 'Pump Product', 'Rinse Nozzle' (press & hold - push
button flashes) & Hopper push buttons On.
To Totally Rinse & Decontaminate the Spray System:
1 Safely park the Cruiser & unfold the boom.
2 Open the Product Tank drain valve (located at the bottom of
the tank) by turning down the yellow drain ball valve handle
and completely drain the tank. Close the valve when empty.
3 Open the storage cabinet of the Quick Filling Station to
access the External G-Hub Controller.
4 Lower the Chemical Induction Hopper & open the hopper
lid.
5 Connect a 3" suction hose (not supplied) to the 3" 'Clean
Fill' camlock coupling with the other end of the hose
connected to a clean water source (refer to 'Tank Filling'
instructions in this chapter).
6 Open the 'Clean Fill' ball valves (Cruiser & suction hose) by
moving the handles down (refer to 'Tank Filling' instructions
in this chapter).
7 Fill the Product Tank with about 1000 litres of clean water.
8 Fill the Rinse Tank full of clean water.
It is important to not close the 'Clean Fill' valve while the pump is running.
Running the pump with a closed suction inlet may damage the pump.
Lower the Chemical Induction Hopper & open the Hopper lid.
9 Lower the Chemical Induction Hopper & open the hopper
lid (refer to 'Chemical Induction Hopper' instructions in this
chapter).
10 Press 'Hopper' push button On.
11 Add the appropriate decontaminating agent to the hopper.
12 Press the Screen Selector push button to select the 'Clean'
screen.
13 Press & hold the 'Rinse nozzle' push button for 2 seconds.
The Product Tank rinse nozzles will flow with liquid sourced
from product tank. The Rinse Nozzle' flashes when On.
If filling the Rinse Tank at the same time as the Product Tank, the 'Fill Rinse Tank'
push button will flash to indicate pausing until the Product Tank reaches 500 litre
level. Rinse Tank filling will then resume as indicated by a solid colour of the push
button. Individual tank filling rate is reduced when filling both tanks at the same
time.