Preparation for Use – Setting Up
4
Press the Boom Prime Time (sec) display touch button to set the boom prime
time.
v) Boom Prime
Boom Prime is used for filling or priming the boom and also to
rinse the boom. Boom Prime sets a time period in which Rapid
Flow will operate before stopping.
To Set the 'Boom Prime Time (sec)':
1 Press the 'Boom Prime Time (sec)' display touch button
and a numerical keypad appears.
2 Press the numbers to set the value at 120 (seconds),
then press Enter. The screen returns to the Agitation
Spray Mode (Auto) screen with '120' displayed in the
'Boom Prime Time (sec)' display.
The 'SAVE' touch button will appear on the left hand side of the screen if a new
value is entered or a change made in the G-Hub system.
If the 'SAVE' touch button is not pressed, then any current changes or entered
value or values will be lost and previous settings will remain.
The 'SAVE' touch button can be pressed at any stage or screen change to
ensure new settings are saved and not accidentally lost.
The screen will return to the G-Hub home screen after the 'SAVE' touch button
is pressed.
78
Press the Tank Levels Tab touch button to open the tank levels screen.
C. Tank Levels Tab
Press the Tank Levels Tab touch button to open the Tank
Levels settings screen and the Tank Levels screen opens
displaying:
i)
Product Tank
ii) Rinse Tank.
i)
Product Tank
The Product Tank settings comprise:
'Useable Tank Volume (L)' - sets the maximum usable
volume in the product tank and should always be less
than the total volume of a tank. For example if the total
volume is 6400L set the useable volume at 6000L. This
setting is used in auto-filling.
'Low Tank Alarm Vol (L)' setting - sets the volume in
litres for the low level alarm in the product tank.
'Low Tank Alarm' setting - selects or deselects the low
level alarm of the product tank. The Low Tank Alarm
when selected warns when the product tank level goes
below the level set.
'Tank Volume Difference (L)' - for setting an alarm if the
Goldacres G-Hub display and the Raven screens are
displaying different amounts by volume in litres. This
function is
.
NOT CURRENTLY IN USE
Press the Product Tank display touch button settings to preset the product tank
functions.
To Set the Usable Tank Volume (L):
1 Press the 'Useable Tank Volume (L)' display touch
button and a numerical keypad appears.
2 Press the numbers to set the value eg, 6000 then press
Enter. The screen returns to the Tank Levels tab screen
with 6000 displayed in the 'Useable Tank Volume (L)'
display.
Actual tank volume may be more eg, 6200 & may be used
if desired.
To Set the Low Tank Alarm Vol (L):
1 Press the 'Low Tank Volume (L)' display touch button
and a numerical keypad appears.
2 Press the numbers to set the value at 1000, then press
Enter. The screen returns to the Tank Levels tab screen
with 1000 displayed in the 'Low Tank Volume (L)'
display.
To Set the Low Tank Alarm:
Press the 'Low Tank Alarm' touch button to select or
deselect the alarm.
GA8701177 REV 2 APRIL 2022