Agilent Technologies N1996A-503 User Reference page 153

Csa spectrum analyzer
Table of Contents

Advertisement

270
Time Stamp
Nanoseconds
271
Limit Packet Coming
272–527
Insertion Loss
Trace – 2
528
Meas Valid
529
Update Trace 1
530
Update Trace 2
531
Display Trace 1
532
Display Trace 2
The remote commands might look like:
:INST:SEL SR
:CONF:TPIL
INIT
*OPC?
CALC:DATA?
Example of what the results looks like from the query command:
#457324.076e+00,4.076e+00,7.691e+00,7.121e+00,6.859e+00,6.785e+00,7.344e+00,8.844e
+00,8.332e+00,6.629e+00,6.395e+00,6.420e+00,6.900e+00,6.568e+00,6.773e+00,5.830e+00
,5.658e+00,5.174e+00,6.215e+00,5.711e+00,7.135e+00,6.449e+00,7.363e+00,6.859e+00,8.9
88e+00,8.422e+00,8.008e+00,5.967e+00,7.660e+00,8.270e+00,9.039e+00,7.615e+00,6.555e
+00,6.773e+00,5.779e+00,6.604e+00,5.715e+00,6.111e+00,4.293e+00,4.666e+00,5.273e+00
,7.570e+00,7.672e+00,9.063e+00,7.189e+00,8.375e+00,7.086e+00,7.705e+00,6.375e+00,5.7
29e+00,5.201e+00,4.670e+00,4.813e+00,5.475e+00,6.320e+00,5.619e+00,6.127e+00,5.447e
+00,5.557e+00,4.242e+00,3.638e+00,3.612e+00,3.921e+00,7.059e+00,7.723e+00,7.732e+00
,4.691e+00,4.334e+00,4.496e+00,6.313e+00,7.145e+00,6.916e+00,5.445e+00,5.336e+00,5.5
74e+00,5.879e+00,6.146e+00,6.020e+00,7.426e+00,7.107e+00,8.645e+00,8.469e+00,8.453e
+00,6.664e+00,6.980e+00,8.199e+00,8.320e+00,7.340e+00,5.730e+00,6.441e+00,5.090e+00
,5.385e+00,3.536e+00,4.676e+00,3.770e+00,5.236e+00,5.355e+00,6.365e+00,6.453e+00,5.9
71e+00,5.836e+00,5.908e+00,5.654e+00,4.836e+00,5.074e+00,5.293e+00,6.773e+00,5.570e
+00,6.369e+00,5.215e+00,5.578e+00,5.402e+00,5.730e+00,6.164e+00,5.969e+00,5.984e+00
,5.133e+00,5.000e+00,6.559e+00,8.992e+00,8.441e+00,7.189e+00,5.563e+00,5.893e+00,5.1
80e+00,5.785e+00,6.230e+00,6.059e+00,5.205e+00,5.191e+00,6.590e+00,8.059e+00,7.887e
+00,7.092e+00,6.754e+00,6.859e+00,7.988e+00,6.822e+00,6.223e+00,5.111e+00,6.703e+00
,7.385e+00,8.016e+00,6.205e+00,6.346e+00,5.990e+00,5.477e+00,7.035e+00,6.217e+00,7.7
Chapter 3
Two Port Insertion Loss Measurement
Time of measurement, instrument clock
nanoseconds
Reserved for future use.
Insertion Loss Trace #2. In dB.
Measurement Validity. 0 = OK, 1 = Over
range
Update Trace #1. 0 = Off, 1 = On.
Update Trace #2. 0 = Off, 1 = On.
Display Trace #1. 0 = Off, 1 = On.
Display Trace #2. 0 = Off, 1 = On.
Mode
153

Advertisement

Table of Contents
loading

This manual is also suitable for:

N1996a-506

Table of Contents