Conducting Signal Measurement; 5G Nr Beam Analysis - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

Chapter 11 Using EMF Analyzer

Conducting signal measurement

Figure 175 EMF spectrum measurement
Conducting signal measurement
The following sections describe how to conduct signal analysis.

5G NR beam analysis

5G NR beam analysis in EMF Analyzer shows the strength of RSRP for each carrier
with the trend of Extrapolated Isotropic EMF Power, Extrapolated Accumulated EMF
Power (Average, Maximum, and Minimum).
Setting measure setup
After configuring the spectrum measurement in
on page
To set measure setup
1
Tap the Setup (
2
Tap Bandwidth/SSB SCS and select the Setting in the pop-up window based on
your need. SSB is abbreviation for Synchronization Signal Block or SS Block and
it refers to Synchronization PBCH block since the synchronization signal and
PBCH channel are packed as a single block that always moves together. SSB
should be detected first in 5G NR frame. See
criteria based on the operating frequency.
3
Tap Sync Raster Offset to set the sync raster resolution to 180 kHz (FR1) or to
720 kHz (FR2) for carrier frequency center using the on-screen keyboard. See
Table 80
resolution.
Page 384
9, you can set the measure setup to continue your measurement.
) icon in the side bar.
below for the sync raster offset range per SSB SCS and sync raster
SPA06MA-O User's Guide
"Configuring spectrum measurements"
Table 79
22145360, R005
below for the setting
April 2021

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa06ma-oSpa06ma

Table of Contents