Ota Datagram - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

To set the limit for
S-SS EVM
Frequency Error
Time Error
Time Alignment
Error
3
Tap the Save icon on the side bar and select the save option from the choices
available for your measurement mode.
Figure 89
Figure 89 LTE/LTE-A TDD OTA control channel measurement

OTA datagram

The OTA Datagram is a time-varying spectral representation that shows how the
power of a signal varies with time. The power allocated to the specific resource block
will be represented with an amplitude axis (in dBm) and the waterfall diagram will
show the trend of past resource block power over certain period. Using a marker
function facilitates analysis of accumulated resource block power for data utilization.
Setting measure setup
After configuring the spectrum measurement in
on page
measurement settings can be saved and recalled as a file by selecting File Type as
Setup and load the file onto the instrument using the Save/Load icons on the side bar.
April 2021
Select and set
Test limits On/Off, High Limit
Test limits On/Off, High/Low Limit
Test limits On/Off, High/Low Limit
Test limits On/Off, High Limit
shows an example of LTE/LTE-A TDD OTA control channel measurement.
9, you can set the measure setup to continue your measurement. The
SPA06MA-O User's Guide
"Configuring spectrum measurements"
22145360, R005
Chapter 6 Using LTE/LTE-A TDD Analyzer
Conducting OTA measurement