Viavi SPA06MA-O R005 User Manual page 35

Table of Contents

Advertisement

3
Tap to switch the selected side to Upper or Lower.
4
Tap the # of Line to set the number of segments for the selected side for upper or
lower up to 50 segments using the on-screen keyboard.
5
Tap the Autoset soft key to automatically set the limit for each segment and
display the line.
6
Tap Offset Up/Down or Offset Left/Right to move the limit line using the on-
screen keyboard.
Table 11
Table 11 Multi Segment Line parameters
Parameter
Autoset
Select Side
Limit
# of Line
Offset Up/Down
(dB)
Offset Left/Right
Edge Limit Table
Editing limit table
1
Tap to switch the select side to Upper or Lower.
2
Tap Select Display Plot to select the segment that you want to edit.
3
Tap the switch to switch the selected segment line to On or Off.
April 2021
describes the parameters displayed for the multi segment line.
Description
Tap to autoset the limit for each segment and display line.
Access: Menu > Limit > Multi Segment Line > Autoset
Tap to set the Select Side to Lower or Upper to select the one
to be displayed.
Access: Menu > Limit > Multi Segment Line > Select Side
Lower/Upper
Tap to select the Limit to On or Off, Once the Autoset is
selected, the Limit changes to On.
Access: Menu > Limit > Multi Segment Line > Limit On/Off
Tap to set the # of Line up to 50 segments for the upper or
lower limit line using the on-screen keyboard.
Access: Menu > Limit > Multi Segment Line > # of Line
Tap to set the Offset Up/Down to move the limit line up or
down when the Display Line Mode is set to On using the on-
screen keyboard.
Access: Menu > Limit > Multi Segment Line > Offset Up/
Down
Tap to set the Offset Left/Right parameter left or right when
the Display Line Mode is set to On using the on-screen key-
board.
Access: Menu > Limit > Multi Segment Line > Offset Left/
Right
Tap to edit the Limit Table. The Limit Table appears on the
bottom of the chart screen.
Access: Menu > Limit > Multi Segment Line > Edit Limit
Table
SPA06MA-O User's Guide
22145360, R005
Chapter 2 Using Spectrum Analyzer
Setting limit
Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa06ma-oSpa06ma

Table of Contents