Table 34 Sync raster offset range per SSB SCS and sync raster resolution
SSB SCS (kHz)
240
Table 35 Sync SCS offset range per SSB SCS and sync SCS resolution
SSB SCS (kHz)
15
30
120
240
To set the limit
1
Tap Menu > Limit.
2
Tap to switch the Test Limits to On or Off to enable or disable Pass/Fail indica-
tion. The result table color for Pass is green, and the result table color for Fail is
red.
3
Optional. Tap the Save hot key on the side bar and select the save option form the
choices available for your measurement mode.
Figure 101
Figure 101 5G NR spectrum emission mask measurement
If Lower Peak or Upper Peak indicate Fail, the mask line becomes red.
April 2021
Sync Raster
Resolution (kHz)
720
Sync Raster
Resolution (kHz)
15
30
120
240
shows an example of spectrum emission mask measurement.
SPA06MA-O User's Guide
22145360, R005
Chapter 7 Using 5G NR Signal Analyzer
Conducting RF measurements
Sync Raster
Offset Range
0 to 48
Sync Raster
Offset Range
0 to 11
0 to 5
0 to 5
0 to 2
SSB Frequency
= Center
frequency
24
SSB Frequency
= Center
Frequency
0
0
0
0
Page 203