Tap any measurement mode from the following choices:

Conducting spectrum measurements

The following sections describe how to conduct spectrum measurements.

Spectrum

Setting measure setup
After configuring the spectrum measurement can configure the measurements just as
in Spectrum mode. For more information, see
on page
Setup and load the file onto the instrument using the Save/Load icons on the side bar.
To set measure setup
1
Tap the Setup (
2
Tap Bandwidth from the following choices: 5 MHz, 10 MHz, 15 MHz, or 20 MHz.
3
Tap to switch Signal Tech Type to TDD or FDD.
To set trigger
1
Tap the Menu > Trigger.
2
Tap Trigger and select the options from Internal, External, or GPS.
April 2021
Spectrum Analysis > Spectrum
RF Analysis > Channel Power, Occupied Bandwidth, Spectrum Emis-
sion Mask, ACLR, Multi-ACLR, or Spurious Emissions
Power vs Time > Power vs Time (Frame), Power vs Time (Slot)
Modulation Analysis > Constellation, Channel Mapper, Control Channel,
Subframe, Frame, or Time Alignment Error
OTA Analysis > OTA Channel Scanner, OTA ID Scanner, OTA Multipath
Profile, OTA Control Channel, OTA Route Map, or Freq/Time Error Varia-
tion
9.The measurement settings can be saved and recalled as a File Type as
) icon in the side bar.
SPA06MA-O User's Guide
"Configuring spectrum measurements"
22145360, R005
Chapter 9 Using 5G DSS Signal Analyzer
Conducting spectrum measurements
Page 291