Spectrum Emission Mask - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

2
Tap to switch the Test Limits to On or Off to enable or disable Pass/Fail indica-
tion.
The result table color for Pass is green, and the result table color for Fail is red.
3
Tap High Limit to set the upper threshold using the on-screen keyboard.
4
Tap Low Limit to set the lower threshold using the on-screen keyboard.
5
Optional: Tap the Save hot key on the side bar and select the save option from the
choices available for your measurement mode.
Figure 40
Figure 40 LTE/LTE-A FDD occupied bandwidth measurement

Spectrum emission mask

The Spectrum Emission Mask (SEM) measurement is to identify and determine the
power level of out-of band spurious emission outside the necessary channel
bandwidth and modulated signal. It measures the power ratio between in-band and
adjacent channels. The SPA06MA-O indicates either Pass or Fail based on the
specified limit of the signal.
Setting measure setup
After configuring the spectrum measurement in
on page
To set measure setup
1
Tap the Setup (
April 2021
shows an example of LTE/LTE-A FDD occupied bandwidth measurement.
NOTE
The Occupied Bandwidth measurement shows both of power across the band
and power bandwidth in a user specified percentage to determine the amount
of spectrum used by a modulated signal. Occupied bandwidth is typically
calculated as the bandwidth containing 99% of the transmitted power.
9, you can set the measure setup to continue your measurement.
) icon in the side bar.
SPA06MA-O User's Guide
"Configuring spectrum measurements"
22145360, R005
Chapter 5 Using LTE/LTE-A FDD Analyzer
Conducting RF measurement
Page 89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spa06ma-oSpa06ma

Table of Contents