Chapter 3 Using Interference Analyzer
Conducting interference measurements
To set display mode
1
Tap Measure Setup > Display.
2
Select the option from the following choices:
3
Tap Measure Setup > Screen Mode.
4
Tap the Screen Mode to select Map or Full.
Figure 24
Figure 24 Interference Finder measurement in map view

Radar chart

If you have identified an interfering signal in your spectrum view, you can move to the
Radar Chart mode and measure RSSI power level through 360° at a location received
by the connected broadband directional antenna so that you can determine the direc-
tion f the source of the interference. Using a set of the AntennaAdvisor Handle that
holds a broadband directional antenna is mandatory in the Radar Chart mode. The
built-in compass, GNSS antenna, and built-in low-noise amplifier (LNA) allow you to
determine the direction of the interference. You can switch the main screen from spec-
trum view to map view and vice versa using the icon on the spectrum view screen.
Before starting the Interference Finder, you need to set Spectrum measurements. See
"Configuring spectrum measurements" on page 9
Page 50
Circum: displays a circumscribed circle that meets three vertices of the
triangle.
Inscribed: displays an inscribed circle that meets the three vertices of the
triangle.
Double: displays both circumscribed and inscribed circles.
Map: displays what is inside the base map with the map image.
Full: displays three location points and defined circle without the map image.
shows an example of the Interference Finder measurement in map view.