4
Tap Sync SCS Offset to fine-tune the offset using the SCS. See
for the sync raster offset range per SSB SCS and sync raster resolution.
5
Tap SSB Center Frequency and input the value using the on-screen keyboard.
6
Tap L to set the maximum number of SS-PBCH blocks within a single SS burst
set (A set of SS being transmitted in 5 ms window of SS transmission) among 4, 8
and 64. Refer to the selection criteria based on the table in Step 2.
7
Tap SSB Auto Search and do the following steps:
a
b
c
8
Tap SSB Periodicity and select the options from 5 ms, 10 ms, 20 ms, 40 ms, 80
ms, 160 ms. The SS burst period (SSB periodicity) is defined by each base
station and network configurable. 20 ms is the default for the initial cell selection.
9
Tap to switch PCI (Physical Cell ID) to Manual or Auto.
10 Tap PCI and input a value from 0 to 1007 using the on-screen keyboard. The PCI
switches to Manual.
11 Tap Test Configuration.
a
April 2021
Tap Search Type and select from the following three options:
-
Full-Raster: You can search in sync raster offset unit that SPA06MA-O
defines (FR1: 180 kHz, FR2: 720 kHz).
Full-Raster & SCS: You can search in SCS unit for the selected SSB
-
(FR1: 15K or 30K, FR2: 120K or 240K).
-
GSCN: If you need to search SSB based on ARFCN raster, it would take
too long time since ARFCN raster is very narrow. Therefore, it is recom-
mended that you define a SSB searching frequency in wider steps. This
is the usage/purpose of GSCN. You can search the frequency corre-
sponding to GSCN in maximum 100 MHz bandwidth of ARFCN that
SPA06MA-O supports.
Tap SSB Auto Search Mode between Manual and Auto.
Manual: You can search SSB automatically with current Preamp and
-
Attenuation setting.
-
Auto: You can search SSB and change Preamp and Attenuation auto-
matically based on input signal level.
Tap to switch SSB Auto Search to Stop to set the SSB periodicity based on
the base station or to Start to search SCS, type, and the number of SSB
automatically. Once Start is selected, the progress bar appears. If it fails to
perform the auto search, a fail message appears and the SSB switches to
Manual.
NOTE
You can go to Menu > Frequency > Center Frequency List to add frequently
used center frequency using the Add button in the Frequency List or to delete
the selected frequency using the Delete button. You can also apply one of the
default frequencies in the Frequency List by tapping the Apply button.
Tap to switch Auto Range to On or Off.