Chapter 5 Using LTE/LTE-A FDD Analyzer
Conducting OTA measurement
4
To select the Cyclic Prefix, tap Cyclic Prefix and select Normal or Extended.
5
Optional: Tap the Save hot key on the side bar and select the save option from the
choices available for your measurement mode.
Figure 57
Figure 57 LTE/LTE-A FDD OTA ID scanner measurement

OTA multipath profile

The Multipath Profile enables you to determine RF environmental conditions of testing
area. It indicates the amount of power of the dominant pilot signal that is dispersed
outside the main correlation peak due to multipath echoes that are expressed in dB.
This value should be very small ideally.
The multipath profile is the result of portions of the original broadcast signal arriving at
the receiving antenna out of phase. This can be caused by the signal being reflected
off objects such as buildings or being refracted through the atmosphere differently
from the main signal.
Setting measure setup
After configuring the spectrum measurement in
on page
measurement settings can be saved and recalled as a file by selecting File Type as
Setup and load the file onto the instrument using the Save/Load icons on the side bar.
To set measure setup
1
Tap the Setup (
2
Tap Bandwidth and select the value from the following choices: 1.4 MHz, 3 MHz,
5 MHz, 10 MHz, 15 MHz or 20 MHz.
Page 118
shows an example of OTA LTE/LTE-A FDD ID scanner measurement.
9, you can set the measure setup to continue your measurement. The
) icon in the side bar.
SPA06MA-O User's Guide
"Configuring spectrum measurements"
22145360, R005
April 2021