Viavi SPA06MA-O R005 User Manual page 218

Table of Contents

Advertisement

Chapter 7 Using 5G NR Signal Analyzer
Conducting RF measurements
c
13 Tap Menu > BW/AVG > Average to set the number of measurements to be aver-
aged using the onscreen keyboard. The input value is from 1 to 100.
Table 33 Setup per operating frequency
Operating
frequency
< 3 GHz
(FR1)
< 3 GHz
(FR1)
< 3 GHz
(FR1)
3 to 6 GHz
(FR1)
3 to 6 GHz
(FR1)
3 to 6 GHz
(FR1)
> 6 GHz
(FR2)
> 6 GHz
(FR2)
Table 34 Sync raster offset range per SSB SCS and sync raster resolution
SSB SCS (kHz)
15
30
120
Page 202
The category is defined with base station type. Set Wide Area BS A/B for
macro cell, Medium Range BS for micro cell, and Local Area Base Station for
pico cell.
Tap Mask Type and select the option from KCA or 3GPP.
You can select the KCA to follow Korea Communications Agency standard
(Korea-specific) or select 3GPP to follow international standard.
L
4
4
4
8
8
8
64
64
Sync Raster
Resolution (kHz)
180
180
720
SPA06MA-O User's Guide
Case
A
{2,8} +14*n
B
{4,8,16,20}
+28*n
C
{2,8} +14*n
A
{2,8} +14*n
B
{4,8,16,20}
+28*n
C
{2,8} +14*n
D
{4,8,16,20}
+28*n
E
{8,12,16,20,3
2,36,40,44}
+56*n
Sync Raster
Offset Range
0 to 250
0 to 506
0 to 92
22145360, R005
Slots in a
SCS
burst period
15 kHz
5 (1 ms)
30 kHz
10 (0.5 ms)
30 kHz
10 (0.5 ms)
15 kHz
5 (1 ms)
30 kHz
10 (0.5 ms)
30 kHz
10 (0.5 ms)
120 kHz
40 (0.125 ms)
240 kHz
80 (62.5
SSB Frequency
= Center
frequency
125
253
46
ms
)
April 2021

Advertisement

Table of Contents
loading

This manual is also suitable for: