Conducting Ota Measurement; Beam Analyzer - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

To set the limit
1
Tap Menu > Limit.
2
Tap to switch the Test Limits to On or Off to enable or disable Pass/Fail indica-
tion. The result table color for Pass is green, and the result table color for Fail is
red.
3
Optional. Tap the Save hot key on the side bar and select the save option form the
choices available for your measurement mode.
Figure 104
Figure 104 5G NR spurious emissions measurement

Conducting OTA measurement

The following sections describe how to conduct OTA analysis.

Beam analyzer

5G NR provides the beamforming profile of each transmission carrier, including the
eight strongest beams and the corresponding power levels during its transmission
period, and includes:
April 2021
shows an example of 5G NR spurious emissions measurement.
NOTE
You can only set the frequency range and attenuation by tapping the
Configuration icon if your setting is 3GPP. If you select the first icon next to the
Range table above, it only shows the selected range and if you select the
second icon next to the Range table, it keeps moving from the first selected
range to the final selected range.
SPA06MA-O User's Guide
22145360, R005
Chapter 7 Using 5G NR Signal Analyzer
Conducting OTA measurement
Page 211