Occupied Bandwidth - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

Chapter 9 Using 5G DSS Signal Analyzer
Conducting RF measurements
Channel power measurement result shows channel power and spectrum density in a
user specified channel bandwidth. The peak to average ratio (PAR) is shown at the
bottom of the screen as well. The shaded area on the display indicates the channel
bandwidth.

Occupied bandwidth

The Occupied Bandwidth measures the percentage of the transmitted power within a
specified bandwidth. The percentage is typically 99%.
Setting measure setup
After configuring the spectrum measurement in
on page
measurement settings can be saved and recalled as a file by selecting File Type as
Setup and load the file onto the instrument using the Save/Load icons on the side bar.
To set measure setup
1
Tap the Setup (
2
Tap Bandwidth from the following choices: 5 MHz, 10 MHz, 15 MHz, or 20 MHz.
3
Tap to switch Signal Tech Type to TDD or FDD.
4
Tap Menu > BW/AVG > Average to set the number of measurements to be aver-
aged using the on-screen keyboard.
The input value range is from 1 to 100.
To set the limit
1
Tap Menu > Limit.
2
Tap to switch the Test Limits to On or Off to enable or disable Pass/Fail indica-
tion. The result table color for Pass is green, and the result table color for Fail is
red.
3
Tap High Limit to set the upper threshold using the on-screen keyboard.
4
Optional. Tap the Save icon on the side bar and select the save option from the
choices available for your measurement mode.
Figure 138
Page 294
9, you can set the measure setup to continue your measurement. The
) icon in the side bar.
shows an example of occupied bandwidth measurement.
SPA06MA-O User's Guide