Conducting Ota Measurement; Ota Channel Scanner - Viavi SPA06MA-O R005 User Manual

Table of Contents

Advertisement

Chapter 6 Using LTE/LTE-A TDD Analyzer

Conducting OTA measurement

Figure 83 LTE/LTE-A TDD carrier aggregation measurement
Conducting OTA measurement
The following sections describe how to conduct OTA analysis.

OTA channel scanner

Setting measure setup
After configuring the spectrum measurement in
on page
measurement settings can be saved and recalled as a file by selecting File Type as
Setup and load the file onto the instrument using the Save/Load icons on the side bar.
To set measure setup
1
Tap the Setup (
2
Tap the MIMO and select 2x2 or 4x4 to select the number of antenna ports.
3
Tap CA Configuration or tap the Configuration (
General Setting and Carrier Setting table appear.
General setting
1
Tap Trigger to set Internal, External or GPS as required.
Page 168
9, you can set the measure setup to continue your measurement. The
) icon in the side bar.
Internal: when starting a signal processing using the internal reference clock
and creating a trigger
External: when starting a signal processing based on the external input
trigger
GPS: When synchronizing the signal processing via the GPS receiver. If you
want to check the time error correctly, set the trigger to GPS
SPA06MA-O User's Guide
"Configuring spectrum measurements"
22145360, R005
) icon.
April 2021