Settings - ABB Relion 650 Series Technical Manual

Bay control
Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

Section 8
Control
8.3.10.4
Table 117:
QCRSV Non group settings (basic)
Name
tCancelRes
ParamRequest1
ParamRequest2
ParamRequest3
ParamRequest4
ParamRequest5
ParamRequest6
ParamRequest7
ParamRequest8
8.3.10.5
248

Settings

Values (Range)
Unit
0.000 - 60.000
s
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Other bays res.
-
Only own bay res.
Operation principle
The Bay reserve (QCRSV) function handles the reservation. QCRSV function
starts to operate in two ways. It starts when there is a request for reservation of the
own bay or if there is a request for reservation from another bay. It is only possible
to reserve the function if it is not currently reserved. The signal that can reserve the
own bay is the input signal RES_RQx (x=1-8) coming from switch controller
(SCWI). The signals for request from another bay are the outputs RE_RQ_B and
V_RE_RQ from function block RESIN. These signals are included in signal
EXCH_OUT from RESIN and are connected to RES_DATA in QCRSV.
The parameters ParamRequestx (x=1-8) are chosen at reservation of the own bay
only (TRUE) or other bays (FALSE). To reserve the own bay only means that no
reservation request RES_BAYS is created.
Reservation request of own bay
If the reservation request comes from the own bay, the function QCRSV has to
know which apparatus the request comes from. This information is available with
the input signal RES_RQx and parameter ParamRequestx (where x=1-8 is the
number of the requesting apparatus). In order to decide if a reservation request of
the current bay can be permitted QCRSV has to know whether the own bay already
is reserved by itself or another bay. This information is available in the output
signal RESERVED.
Step
Default
0.001
10.000
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
-
Only own bay res.
1MRK 511 424-UEN B
Description
Supervision time for canceling the
reservation
Reservation of the own bay only, at
selection of apparatus 1
Reservation of the own bay only, at
selection of apparatus 2
Reservation of the own bay only, at
selection of apparatus 3
Reservation of the own bay only, at
selection of apparatus 4
Reservation of the own bay only, at
selection of apparatus 5
Reservation of the own bay only, at
selection of apparatus 6
Reservation of the own bay only, at
selection of apparatus 7
Reservation of the own bay only, at
selection of apparatus 8
Bay control REC650 2.2 IEC
Technical manual
PID-3561-SETTINGS v7
M13505-4 v3
M13505-7 v2