Setting Examples

While referring to the setting examples in the link units, set the transmission specifications.
The examples below explain the setting in the NJ-CPU-B16 (link unit), the NJ-RS4 and the NJ-RS2.
1) NJ-CPU-B16
In the NJ-CPU-B16, use the parameter (50H) for setting.
Parameter
2) NJ-RS4
In the NJ-RS4, use each switch for setting.
Switch
position
Mode
Front face
Station number
Terminal resistor
Rear face
Communication
condition
3) NJ-RS2
In the NJ-RS2, use each switch for setting.
Switch
position
Mode
Rear face
Communication
condition
Connection of FLEX-PC N Series PLC (Manufactured by Fuji Electric) 16
50H
Setting item
Description
MODE SW
Station number
setting SW × 10
Station number
setting SW × 1
Selector SW 1
Selector SW 2
DIP .SW
Setting item
Description
MODE SW
DIP .SW
Data value
Baud rate: 19200 bps
Stop bit: 1 bit
0057H
Character length: 8 bits
Parity: Odd
Command setting type:
3
asynchronous system, no protocol
Upper digit
(Correspond to the station
number in the GOT-F900.)
Lower digit
ON
Receive line provided
ON
Transmission line provided
1:OFF
Set the condition using switches:
2~8:ON
19200 bps, 7 bits, 1 stop bit and even parity
Command setting type:
1
asynchronous system, no protocol
1:OFF
Set the condition using switches:
2 to 8:ON
19200 bps, 7 bits, 1 stop bit and even parity
Contents of setting
Remarks
Remarks
16-5
11
12
13
14
15
16
17
18
19
20