GOT-F900 SERIES (CONNECTION)
Note
Even if momentary power failure of less than 5 ms occurs in the power supply, the F930GOT/
F930GOT-K/F940(W)GOT continues the operation.
If long-time power failure or voltage drop occurs, the F930GOT/F940(W)GOT stops the operation.
When the power supply is recovered, the F930GOT/F940(W)GOT restarts the operation.
Use electric wires of 0.75 mm
occur. Use solderless terminals for M3, and tighten them securely with the tightening torque of 0.5 to
0.8 N•m so that troubles are not caused.
Index of each part
(examples: F940GOT and F930GOT-K)
F940GOT
F930GOT-K
Installation and Wiring of F920GOT-K/F930GOT(-K)/F940(W)GOT 4
2
or more in wiring of the power supply so that voltage drop does not
For the F920GOT-K, F930GOT(-K) and F940WGOT, refer
to corresponding sections and paragraphs shown below.
24VDC
+
-
Controlling the ON/OFF status of the backlight
⇒ 23.3
Connecting the PLC
⇒ Section 8 and later
(described for each connected PLC)
- When connecting the FX Series PLC...Section 8
- When connecting the A Series PLC...Section 9
Connecting the PC (for screen data transfer)
⇒ 6.2.1
Connecting the PC
(for sequence program transfer and monitoring)
⇒ 6.2.2
Function to connect two or more GOT units
⇒ Section 7
Detecting voltage drop of the battery
⇒ 23.4
Wiring the power supply
⇒ 4.7
Assigning functions to the function keys
Preparing the key name sheet
⇒ 4.8
4-2