Mitsubishi Electric F920GOT-K Hardware Manual page 469

Got-f900 series graphic operation terminal
Table of Contents

Advertisement

GOT-F900 SERIES (CONNECTION)
e)Set the following.
[Change method] Change the connection type of the already created data as follows.
a)Open GT Designer2.
b)Click the [Project]-[Open] button.
c)Open (read) the screen data to be changed.
d)On the menu, select "Common"-"System Environment".
Connection of Machine Controller CP9200SH (PLC Manufactured by Yaskawa Electric) 17
Operation
Port
: RS-422
RS-232C
Type
: CPU
Station No.
: 01 to 16 ("00" is treated as "01".)
GOT Station No. : −
In the case of F943 Handy GOT
Without regard to the port setting (RS-422 or RS-232C), the
COM0 side of the RS-232C is fixed for PLC connection.
- For the contents of setting, refer to c) of [Creation] above.
- For selection of the RS-422 or the RS-232C on the Machine
Controller PLCs, refer to e) of [Creation] above.
Display (screen name)
The "Select Project"
dialog box appears.
The "System
Environment" dialog box
appears.
17-9
11
12
13
14
15
16
17
18
19
20