cannot be transferred.
Contents of trouble
Connection of FREQROL (S500/E500/A500) Inverter 13
Check points and countermeasures
A bar code reader or printer is connected.
(Such equipment cannot be connected to the FREQROL
inverter.)
• Causes
The RS-232C connector to which the personal computer is
connected is set to be used for another piece of equipment.
• Countermeasures
In the GOT-F900, select by hand "SELECT MODE"-"OTHER
MODE"-"DATA TRANSFER".
Or set a bar code reader to invalid and a printer" to "DON'T
USE".
Something is wrong with the cable between the GOT-F900
and the personal computer.
• Causes
The connected cable is not proper. Or cable connection is
not correct.
• Countermeasures
Check the cable.