[Change method] Change the connection type of the already created data as follows.
Connection of SIMATIC S7-200/300/400 Series PLC (Manufactured by Siemens AG) 20
Operation
d)Setting the port (RS-232C) of the GOT-F900
Click "Auxially Setting" in the tree of the system environment
menu.
Click the check box of "Use Serial Port, Setup, Language, Menu
Key" to give a check mark ($).
Click "Got Setup" in the tree of the system environment menu.
e)Set the following.
Port
: RS-232C
Type
: CPU
(S7-200)
Station No.
: 1 to 31
GOT Station No. : 0 to 31
(S7-300)
Station No.
: 02 to 31
("00" and "01" are treated as "02".)
GOT Station No.:−
In the case of F943 Handy GOT
Without regard to the port setting (RS-422 or RS-232C), the
COM0 side of the RS-232C is fixed for PLC connection.
a)Open GT Designer2.
b)Click the [Project]-[Open] button.
c)Open (read) the screen data to be changed.
d)On the menu, select "Common"-"System Environment".
- For the contents of setting, refer to c) of [Creation] above.
- For selection of the RS-232C on the SIMATIC Series PLCs, refer
to e) of [Creation] above.
Display (screen name)
The "Auxiliary Settings"
dialog box appears.
The "Select Project"
dialog box appears.
The "System
Environment" dialog box
appears.
20-14