GOT-F900 SERIES (CONNECTION)
19.6
Caution on Use of SLC500/MicroLogix Series PLC
When using the GOT-F900 connected to the SLC500/Micro Logix Series PLC, observe the following
caution on use.
19.6.1
Device setting in advance
The user is required to set devices to be used for the SLC500/MicroLogix Series. Accordingly, if devices
to be monitored or set are not specified in the PLC, a communication error occurs.
19.6.2
Caution on use of the sampling function
The GOT-F900 is always monitoring sampling devices in the sampling mode even if the sampling
condition is not set. As a result, a communication error occurs if sampling devices are not present. In
such a case, change sampling devices or set devices in the SLC500/MicroLogix Series.
Connection of SLC500/MicroLogix Series PLC (Manufactured by Allen-Bradley) 19