GOT-F900 SERIES (CONNECTION)
2) In the case of C200H Series (host link unit)
In the host link unit C200H-LK201-V1, execute the setting using each switch.
Switch
position
Front face
Rear face
Setting Example
Switch setting on the
front face
LK201-V1
RUN
RCV
SW1
SW3
Switch setting on the
rear face
Connection of SYSMAC C Series PLC (Manufactured by Omron) 15
Setting item
Unit number
Transmission speed
Communication
condition
Procedure
5V power supply
CTS changeover
XM
ERROR
SW2
SW4
Switch setting
SW1
SW2
SW3
6
SW4
2
DIP . SW
ON
No.3
DIP . SW
OFF
No.4
Selector SW Upper side External
1) SW1 and SW2 (setting of unit number)
Set "SW1: 0, SW2: 0" (to set the unit number 00).
2) SW3 (setting of transmission speed)
Set "SW3:6" (to set 19200bps).
3) SW4 (setting of command level, parity and
transmission code)
Set "SW4:2" (to set even parity, 7-bit ASCII
and 2 stop bits).
4) 5V supply SW
SW No.
1
Not used (to be set to OFF)
2
3
1:N procedure
5V is supplied.
4
5) CTS selector SW
Set the switch to the 0V side to
always set the CTS to ON.
Set the switch to the external side to
receive from the outside.
Usually, set this switch to the 0V side.
Remarks
BCD upper digit (Correspond to the station
number of the GOT-F900.)
BCD lower digit
19200bps
7-bit ASCII, 2 stop bits, even parity, command
level 1, 2 or 3
1:N procedure
5V is not supplied.
ON
OFF
1:1 procedure
5V is not
supplied.
15-10