GOT-F900 SERIES (CONNECTION)
d)Setting the port (RS-422 or RS-232C) of the GOT-F900
RS-422
e)Set the following.
connection
RS-232C
e)Set the following.
connection
[Change method] Change the connection type of the already created data as follows.
a)Open GT Designer2.
b)Click the [Project]-[Open] button.
c)Open (read) the screen data to be changed.
d)On the menu, select "Common"-"System Environment".
Operation
Click "Auxiliary Setting" in the tree of the system environment
menu.
Click the check box of "Use Serial Port, Setup, Language, Menu
Key" to give a check mark ($).
Click "Got Setup" in the tree of the system environment menu.
Port
: RS-422
Type
: CPU
Station No.
: 00 (01 to 31 for microcomputer connection)
GOT Station No. : −
Port
: RS-232C
Type
: CPU
Station No.
: 00 (01 to 31 for microcomputer connection)
GOT Station No. : −
In the case of F943 Handy GOT
Without regard to the port setting (RS-422 or RS-232C), the
COM0 side of the RS-232C is fixed for PLC connection.
- For the contents of setting, refer to c) of [Creation] above.
- For selection of the RS-422 or the RS-232C, refer to e) of
[Creation] above.
Connection of Two or More GOT Units 7
Display (screen name)
The "Project Auxiliary
Settings" dialog box
appears.
The "Select Project"
dialog box appears.
The "System
Environment" dialog box
appears.
7-15
1
2
3
4
5
6
7
8
9
10