Mitsubishi Electric F920GOT-K Hardware Manual page 134

Got-f900 series graphic operation terminal
Table of Contents

Advertisement

GOT-F900 SERIES (CONNECTION)
Handy GOT RH model
1) Switch assignment
The figure below shows the switch assignment. Each switch is expressed in abbreviations as follows.
K S W
L 1
L 2
P O W E R
S W 1
S W 2
Switches requiring external wiring
The following switches have to be connected to the PLC or external input equipment through the
operation switch connector.
-
Operation switches
-
Grip switch
LEDs not requiring external wiring
Because the following switch and LEDs are connected to the display unit CPU and ready for serial
communication with the PLC through the communication port, they do not have to be wired.
-
Indicator LED for grip switch
2) Internal wiring of switches
Each switch on the previous page is wired inside the Handy GOT as shown below.
The connectors CN1 to CN5 (except CN3) are connected to the PLC via an external cable (F9GT-
RHCAB-"M).
Power
supply
RS-422 or RS-232C
(for externally
connected
equipment)
Operation
switches
Grip switch
Emergency
stop switch
Keylock
switch
E S 1
L 3
L 4
G R I P S W
S W 3
S W 4
L 5
CN1
DC24V+
Power
supply
DC24G
circuit
FG
CN2
CN2
SW1
SW2
SW3
SW4
SW-COM
CN4
DSW1
DSW2
CN5
ES1-1
ES1-2
ES1-1
ES1-2
CN6
KSW-2
KSW-C
KSW-1
Abbreviation
SW1~SW4
ES1
KSW1,KSW2
L1~L4
G r i p
s w i t c h
L5
DSW1,DSW2
-
Emergency stop switch
-
Keylock switch
-
Indicator LEDs for operation switches
Display circuit
LCD panel
Touch switch circuit
CPU/communication circuit
CPU memory
communication
Installation and Wiring of Handy GOT 5
Name
Operation switches
Emergency stop switch
Keylock switch
Indicator LEDs for
operation switches
Indicator LED for grip
switch
Grip switch
CN3
RS-232C
(for personal
computer)
Serial
unit
Reference
5.9.1
5.10
5.13
5.9.1
5.12.2
5.12
Grip switch
Indicator LEDs
for operation
switches
L1(SW1)
L2(SW2)
L3(SW3)
L4(SW4)
L5
(GRIP SW)
5-32

Hide quick links:

Advertisement