GOT-F900 SERIES (CONNECTION)
16.5

Setting of Connected Equipment for GOT

The setting for connection to the FLEX-PC N Series PLC can be executed using the GOT-F900 and the
screen creation software (GT Designer2 or DU/WIN).
Setting the Connection Type
Set the connection type in accordance with the connected equipment as shown in the table below.
Have in mind that the NJ-CPU-B16 (link unit) requires CPU direct connection.
Connected equipment
[classification in manual]
[Link unit]
NJ-CPU-B16(RS-232C)
[Link unit]
NB-RS1-AC(RS-422/RS-232C)
NJ-RS4(RS-422)
NJ-RS2(RS-232C)
NS-RS1(RS-422/RS-232C)
1) GOT-F900 Series
When the main menu screen change operation is disabled.
a)While pressing and holding the upper left corner of the screen,
turn on the power. Keep holding the upper left corner for about
25 seconds more.
Then, press "END" at the upper right corner.
b)Press "PLC TYPE".
c) Set the following.
PLC TYPE:FUJI N SERIES
CONNECTION:CPU PORT (RS-232C)
DST STATION # (STATION #) : 00 to 31
GOT STATION # (−)
When the main menu screen change operation is enabled.
a).Press the upper left corner of the screen. (The position to be
pressed can be changed in the GOT and the screen creation
software.)
b).Press "OTHER MODE" on the menu.
c) .Press "SET-UP MODE" on the menu.
d)Press "PLC TYPE".
e)Set the following.
PLC TYPE: FUJI N SERIES
CONNECTION:CPU PORT (RS-232C)
DST STATION # (STATION #) : 00 to 31
GOT STATION # (−)
- When the screen data is transferred to the GOT-F900, the old data including the PLC type, connection type,
and station number are overwritten.
Connection of FLEX-PC N Series PLC (Manufactured by Fuji Electric) 16
GOT-F900
CONNECTION
CPU direct connection (RS-232C)
Link connection (RS-422) or
link connection (RS-232C)
Operation
LINK PORT (RS-422)
LINK PORT (RS-232C)
: −
Operation
LINK PORT (RS-422)
LINK PORT (RS-232C)
: −
DU/WIN
Type
Executes communication as
programming port
Executes communication as link unit
Display (screen name)
The "LANGUAGE" screen appears.
The "SET-UP MODE" screen appears.
The "PLC TYPE" screen appears.
Display (screen name)
The "SELECT MODE" screen appears.
The "OTHER MODE" screen appears.
The "SET-UP MODE" screen appears.
The "PLC TYPE" screen appears.
Remarks
16-7
11
12
13
14
15
16
17
18
19
20