Direct command mode for position control
In the direct command mode, the target position and maximum speed can be set through commu-
nication.
Pr.
1220
B100
● The point table is set as follows in the direct command mode. (The setting is applied when the
start signal is turned ON.)
Pr.1220
setting
1
2
Tab. A-6:
Same as point table 1. However, even when continuous operation is set in the auxiliary function,
individual operation is applied.
The direct command mode is available only for individual operation. The dwell time is invalid.
A - 42
Name
Target position/speed selection
Target
Maximum
position
speed
Direct
Point table 1
command
Direct
Direct
command
command
Setting the point table
Initial value
Setting range Description
0
0
1
2
Acceleration
Deceleration
time
time
Pr.7
Pr.8
Appendix
Target position and maximum
speed: Point table
Target position: Direct command
Maximum speed: Point table
Target position and maximum
speed: Direct command
Auxiliary
Dwell time
function
Invalid
Invalid