Model 4200-SCS Reference Manual
Figure 6-400
Windows caption bar
Figure 6-401
Display status bar
NOTE
Figure 6-402
UID numbers in Project Navigator
4200-901-01 Rev. S / May 2017
When Gradient caption is not checked, a standard Windows caption bar is displayed
above the KITE window as follows:
Display status bar: When Display status bar is checked, the status bar (see below) is
displayed at the bottom of the KITE window.
Otherwise, the status bar is not displayed.
Display clock on status bar: When Display clock on status bar is checked, the clock on
the status bar (see pervious item) is displayed at the bottom of the KITE window. Otherwise,
the clock is not displayed.
On older 233 MHz 4200-SCS systems, when Display clock on status bar is
checked, the screen saver for the flat panel display will not activate. Refer to
Administration
in Section 10 for more information.
Show UID in project tree: When Show UID in project tree is checked, the Unique
IDentifier (UID) numbers are displayed in the Project Navigator (see below). Otherwise, the
UID numbers are not displayed.
Show UID in project tree checked
Reset GPIB devices at startup: If checked, the GPIB devices in the system will reset to
their default settings at startup.
PMU: Allow unsettled measurements:
If checked, permits all 4225-PMU instrument cards to ignore the minimum timing versus
measure range relationship shown in the chart
for advanced users, as spot mean results will not be settled, which may cause a variety of
operational issues: inconsistent current measure range-changing on the 4225-PMU or
4225-RPM; lack of proper
correlation between PMU or PMU+RPM results and SMU results. See
settling times versus current measure range
Load default project: When Load default project is checked, the project that is specified
under Default Project is loaded every time KITE is started (refer to
project).
Display workbook mode: When Display workbook mode is checked, window tabs are
displayed at the bottoms of project windows, initialization and termination plan windows,
subsite-plan windows, device-plan windows, and ITM and UTM windows. Otherwise, the
tabs are not displayed. See
Return to
Section 6: Keithley Interactive Test Environment (KITE)
Show UID in project tree unchecked
Load line effect compensation (LLEC) for the PMU
for additional information.
Figure
6-403.
Section Topics
(Figure
16-45). This is only recommended
PMU minimum
Specifying a default
System
and lack of
6-339

Advertisement

Table of Contents
loading

Table of Contents